background image

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

BNI PNT-502-105-Z015 

IP67 Modules  

4 IO-Link/In-/Outputs,12 In-/Outputs 

User’s Guide 

 

Summary of Contents for BNI PNT-502-105-Z015

Page 1: ...BNI PNT 502 105 Z015 IP67 Modules 4 IO Link In Outputs 12 In Outputs User s Guide...

Page 2: ...ort 7 IO Link Port 7 4 Technical data 8 4 1 Dimensions 8 4 2 Mechanical data 8 4 3 Operating conditions 8 4 4 Electrical data 8 4 5 PROFINET 9 4 6 Function indicators 9 Modul status 9 Port 9 5 Integra...

Page 3: ...www balluff com 2 Content 7 Appendix 16 7 1 Included material 16 7 2 Ordercode 16 7 3 Order Information 16...

Page 4: ...h bullet points Entry 1 Entry 2 Actions Action instructions are indicated by a preceding triangle The result of an action is indicated by an arrow Action instruction 1 Action result Action instruction...

Page 5: ...es accordingly The device must be powered only using an approved power supply see chapter 4 Technical data Only approved cable may be used Operating and testing The operator is responsible for observi...

Page 6: ...y 4 Power Supply In 5 Status LED 6 Port 1 Standard I O 7 Pin Port LED Signal status 8 Port 3 Standard I O 9 Port 5 IO Link Standard I O 10 Port 7 IO Link Standard I O 11 Port 6 IO Link Standard I O 12...

Page 7: ...on 1 GND actuator power supply 0 V 2 GND Bus Sensor power supply 0 V 3 Grounding FE 4 Bus Sensor power supply 24 V 5 Actuator power supply 24 V Note Provide sensor bus power and actuator power from se...

Page 8: ...sor inputs follow the input guideline per EN61131 2 type 2 Note Each output serves a maximum current of 2 0 amperes The IO Link Ports only 1 6 A Total current of the module has to be lower than 4 ampe...

Page 9: ...female Dimensions W x H x D in mm 68 x 224 x 30 9 Mounting type 2 hole screw mount Ground strap attachment M4 Weight Approx 670 gr 4 3 Operating conditions Operating temperature Ta Storage temperature...

Page 10: ...ded diagnosis present system error red flashing DCP signal service is initiated via the bus BF off No error red No configuration or low speed physical link or no physical link red flashing No data exc...

Page 11: ...are stored in GSDML files Generic Station Description Markup Language The GSDML files are available in 2 languages for downloading over the Internet www balluff com The data modules of an IO Link mod...

Page 12: ...Balluff Network Interface Profinet BNI PNT 502 105 Z015 www balluff com 11 5 Integration Including the module to Configuration Object properties...

Page 13: ...www balluff com 12 5 Integration Naming of the device Configuration of the Ethernet address...

Page 14: ...Balluff Network Interface Profinet BNI PNT 502 105 Z015 www balluff com 13 5 Integration Finish Hardware Configuration Integration to the ProfiNet network...

Page 15: ...www balluff com 14 5 Integration Scanning the system Succesfully integrated in the system Selection of the Device names MAC ID of the Device MAC ID of the Device Assigned Device name...

Page 16: ...rent webpages just click on the corresponding text 6 3 Diagnostic Process On this page you can get some information about the module s current process data by having a look at the led If a IO Link Dev...

Page 17: ...I PNT 502 105 Z015 Balluff Network Interface ProfiNet Functions 502 IP 67 IO Link Master Modul Variants 105 Display version 2 port switch Mechanical version Z015 Material Die cast zinc Uplink 2 x M12x...

Page 18: ...Balluff Network Interface Profinet BNI PNT 502 105 Z015 www balluff com 17 Notes...

Page 19: ...www balluff com 18 Notes...

Page 20: ...PNT 502 105 Z015 www balluff com 19 www balluff com Balluff GmbH Schurwaldstrasse 9 73765 Neuhausen a d F Germany Tel 49 7158 173 0 Fax 49 7158 5010 balluff balluff de Nr 883220 E Edition 1109 Revise...