www.balluff.com
11
5
Configuration: "Extension Off"
Parameter Data
5.4.
/ Demand Data
DPP
ISDU
Parameter
Data
width
Access
rights
Default value
Index
Index
Subin
dex
Ident
if
ic
a
ti
on
dat
a
07
hex
Vendor ID
2 bytes
R
e
a
d
o
n
ly
0378
hex
08
hex
09
hex
Device ID
3 bytes
05 0D 20
hex
0A
hex
0B
hex
10
hex
0
Vendor Name
-
BALLUFF
11
hex
0
Vendor text
-
www.balluff.com
12
hex
0
Product
Name
-
BNI IOL-302-002-Z046
13
hex
0
Product ID
-
BNI00AU
14
hex
0
Product text
-
M8 sensor/actuator hub
15
hex
0
Serial number
16 bytes
0hex
16
hex
0
Hardware
revision
17
hex
0
Firmware
revision
18
hex
0
Application-
specific tag
32 bytes
0hex
DPP
ISDU
Parameter
Data width
Access rights
Default
Value
Index
Index Subindex
P
a
ra
m
e
te
r
dat
a
40
hex
64
0
1-16
Inversion of the inputs
2 bytes
Read/write
0
hex
41
hex
65
0
1-16
Config. inputs/outputs
2 bytes
Read/write
0
hex
42
hex
66
0
1-16
Safe state on Pin 4
4 bytes
Read/write
0
hex
44
hex
68
0
1-24
Voltage monitoring
3 bytes
Read
-
45
hex
69
0
1-16
Output monitoring
2 bytes
Read
-
46
hex
70
0
1-16
Actuator warning
2 bytes
Read
-
54
hex
84
0
Serial number
16 bytes
Read/write
16x00
hex
55
hex
85
0
Extension port
1 byte
Read/write
-