www.balluff.com
21
english
7
IO-Link interface (continued)
7.5
Parameter data
Index
Subindex
Parameter
Size
Access
Data storage
MDC (measurement data channel)
(see section 7.5.1)
0x00C1 (193)
0
Offset
4 bytes
Read/Write
X
0x00C2 (194)
0
Preset
4 bytes
Read/Write
X
0x00C3 (195)
0
Output Characteristics
1 byte
Read/Write
X
0x00C4 (196)
0
Enable Detection Range
1 byte
Read/Write
X
0x4080 (16512) 0, 1, 2, 3, 4
MDC Describer
11 bytes
Read Only
0x0202 (514)
0, 1, 2
Physical Measurement Limits
8 byte
Read/Write
X
SSC (switching signal channels)
0x003A (58)
0
Teach-In Select
1 byte
Read/Write
0x003B (59)
0
Teach-In Result
1 byte
Read Only
0x003C (60)
0, 1, 2
SSC1 Parameter
8 byte
Read/Write
X
0x003D (61)
0, 1, 2, 3
SSC1 Configurartion
4 bytes
Read/Write
X
0x003E (62)
0, 1, 2
SSC2 Parameter
8 byte
Read/Write
X
0x003F (63)
0, 1, 2, 3
SSC2 Configurartion
4 bytes
Read/Write
X
0x4000 (16384) 0, 1, 2
SSC3 Parameter
8 byte
Read/Write
X
0x4001 (16385) 0, 1, 2, 3
SSC3 Configurartion
4 bytes
Read/Write
X
0x4002 (16386) 0, 1, 2
SSC4 Parameter
8 byte
Read/Write
X
0x4003 (16387) 0, 1, 2, 3
SSC4 Configurartion
4 bytes
Read/Write
X
Device Configuration
0x00B4 (180)
0, 1, 2
Output Type (see section 7.5.3)
2 bytes
Read/Write
X
0x00F8 (248)
0, 1, 2
Diagnosis Suppression Configuration
(see section 7.5.4)
2 bytes
Read/Write
X
Condition Monitoring
0x0052 (82)
0, 1, 2, 3, 4, 5
Device Temperature (see section 7.5.5)
10 bytes
Read Only
0x0053 (83)
0, 1, 2
Temperature Thresholds (see section 7.5.6)
4 bytes
Read/Write
X
0x0057 (87)
0, 1, 2, 3
Operating Hours (see section 7.5.7)
12 bytes
Read Only
0x0058 (88)
0
Boot Cycle counter (see section 7.5.8)
4 bytes
Read Only
System Parameters
0x0003 (3)
0, 1, 2, 3, 4, 5
Data Storage (see section 7.5.9)
72 bytes
Read/Write
0x000C (12)
0
Device Access Locks (see section 7.5.10)
2 bytes
Read/Write
X
0x000D (13)
0, 1, 2, 3, 4
ProfileCharacteristic (see section 7.5.11)
8 bytes
Read Only
0x000E (14)
0, 1, 2, 3
PD Input Descriptor (see section 7.5.12)
9 byte
Read Only
Tab. 7-6: Parameter data of IO-Link interface