www.balluff.com
21
Accessories are not included in the scope of delivery and
must be ordered separately.
8.1
Magnetic tape
When selecting the magnetic tape, make sure
the magnetic tape and sensor head are
compatible. This particularly applies to the
following factors:
– Pole width (1 or 2 mm), see section 3.2.1
– Reference points (none, one, two or more
(fixed periodic)), see section 3.3
For a complete technical description and assembly
instructions for magnetic tapes and rotative magnetic
tapes (magnetic rings), see the separate user's guides at
www.balluff.com
.
8.2
Connector
Permissible bending radius
– Fixed routing
7.5 x outer diameter
– Moved
15 x outer diameter
Cable material
PUR
Plug
M12x1, 12-pin
Fig. 8-1:
~44
M12x1
Ø≤5.2
Ø14.5
M12 plug, 12-pin
For the pin assignment and colors, see Tab. 4-2
Type
Ordering
code
BCC M41C-0000-1A-169-PS0C08-020-C009 BCC09MW
BCC M41C-0000-1A-169-PS0C08-050-C009 BCC09MY
BCC M41C-0000-1A-169-PS0C08-100-C009 BCC09MZ
1)
BCC M41C-0000-1A-169-PS0C08-150-C009 BCC09N0
1)
BCC M41C-0000-1A-169-PS0C08-200-C009 BCC09N1
1)
1)
For cable lengths ≥ 10 m, the controller for the A/B interface BML-S1F_…
must be equipped with a protection circuit against surge (EN 61000-4-5).
Examples:
– BCC M41C-0000-1A-169-PS0C08-
020
-C009 = cable
length 2 m
– BCC M41C-0000-1A-169-PS0C08-
050
-C009 = cable
length 5 m
8.3
Guided magnetic tape position measuring
system
Sensor guide consisting of a
BML-R01-M_ _ _
aluminum
rail to hold the magnetic tape and a
BML-C02
(BAM01MH)
slide with gliders to guide the sensor head.
8.4
BDD counter
BDD 611-R3Q4-0-52-N-00 (BAE004K)
– One-axis counter for all BML-S…
– Min. edge distance code E, F, G, H, K, L, M, N, P, R
BDD 622-R3Q4-0-52-N-00 (BAE004M)
– Two-axis counter for all BML-S…
– Min. edge distance code E, F, G, H, K, L, M, N, P, R
BDD 632-R3Q4-0-52-N-00 (BAE004P)
– Three-axis counter for all BML-S…
– Min. edge distance code E, F, G, H, K, L, M, N, P, R
All counters need a 24 V DC operating voltage. A power
supply for rail mounting
BAE PS-XA-1W-24-007-001
(BAE0001)
is available for operation with 230 V.
8
Accessories
BML-S1F_-A/Q _ _ _ -M_ _ 0- _ 0-…
Incremental Magnetic Linear Encoder
english
Summary of Contents for BML-S1F Series
Page 2: ...www balluff com...
Page 28: ...www balluff com...
Page 54: ...www balluff com...
Page 80: ...www balluff com...
Page 106: ...www balluff com...