www.balluff.com

2

No. 946033 EN · B20; Subject to changes.

BMF 415KW-HA _ _ _ -W-5- _ _ -…

Magnetic Field Sensors

Balluff GmbH

Schurwaldstrasse 9

73765 Neuhausen a.d.F.

Germany

Phone + 49 7158 173-0

Fax +49 7158 5010

[email protected]

english

Electrical connection (continued)

3-pin sensors

4-pin sensors

M8, 

normally 

open

M12, 

normally 

open

M8, 

IO-Link, 

Class A

M12, 

IO-Link, 

Class A

Pin

Wire color

Signal

Pin 1 Brown

UB+ (operating voltage, +24 V)

Pin 2 White

not connected or not present

Pin 3 Blue

UB– (operating voltage, GND/0 V)

Pin 4 Black

OUT1 (switching output) or 

C/Q for IO-Link, configurable

Installation

1. 

Place piston rod of the pneumatic cylinder in the 

desired position.

2. 

Move the sensor in the T-slot until the area in which the 

yellow LED remains consistently on is detected.

 

Fix sensor in the middle of this switching range.

3. 

Use a 2 mm Allen key or No. 2 screwdriver to affix the 

sensor in the middle of the switching area.

2.0

0.7 Nm

4. 

Optional: Attach protective shield to sensor body.

5. 

Use cable clip to fix cable in the slot.

Startup

  DANGER

Uncontrolled system movement

When starting up, if the sensor is part of a closed loop 
system whose parameters have not yet been set, the 
system may perform uncontrolled movements. This could 
result in personal injury and equipment damage.

 

Persons must keep away from the system’s hazar-
dous zones.

 

Startup must be performed only by trained technical 
personnel.

 

Observe the safety instructions of the equipment or 
system manufacturer.

1. 

Check connections for tightness and correct polarity. 

Replace damaged connections.

2. 

Turn on the system.

3. 

Check measured values and adjustable parameters 

and readjust the BMF if necessary.

Check for the correct values, especially after 

replacing the BMF or after repair by the manu-

facturer.

Operating notes

  CAUTION

Elevated housing temperature

If the installation does not provide sufficient thermal 
coupling, the surface temperature of the BMF may rise to 
over 50 °C and cause burns when touched.

 

Improve the thermal coupling of the installation.

 

Reduce the load.

 

Do not touch the surface.

–  Regularly check function of the BMF and all associated 

components.

–  Take the BMF out of service whenever there is a mal-

function.

–  Secure the system against unauthorized use.
–  Check fasteners and re-tighten if needed.

–  The sensor features overload protection. After the 

overload is eliminated, the sensor is once again func-

tional.