8
3.2
LED display
Green (power indicator)
Red (fault indicator)
Yellow (function indicator)
LED
Meaning
Color
Function
State
Green
Power indicator
On
The sensor is operating normally. The required
operating voltage is available.
Flashes
(900 ms on : 100 ms off)
IO-Link communication is active.
Yellow
Function indicator On
The switching point has been reached and the
switching conditions are met provided no fault is
detected. The axial magnetic field (measured by the
sensor at the bottom of the slot) is ≥ 6.5 mT and
thereby corresponds to the assured magnetic
switching field strength H
a
1)
.
Flashes
(250 ms on : 250 ms off)
The switching point has been reached and the output
is switched. The measured magnetic field strength is
however sufficient only for operation under the current
ambient conditions and the current sensor
temperature, and corresponds to the rated switching
field strength H
n
of typically 6 mT.
►
Check whether the sensor still detects the set
switching point after a temperature change and
reset the switching point if necessary.
Red
Fault indicator
On
(green and yellow LEDs
are
off
)
A hardware error was detected. This may be caused
by the following:
– Excessive load current on the switching output (I
load
+5 %)
– Output driver too hot (T
driver
≥ 125 °C)
– Sensor supply voltage too low (U
B
on L+ < 6.5 V)
Flashes
(250 ms on : 250 ms off,
green and yellow LEDs
are
off
)
Fault / communication error on the internal data bus
All LEDs
(green/yellow/red)
Special fault
indicator
Flash
(250 ms on : 250 ms off)
Error during initiation
1)
The assured switching field strength is the required magnetic minimum
field strength over the entire temperature range, measured axially in the
slot base.
Tab. 3-1: LED display
3
Construction and function (continued)
BMF 415KW-HA _ _ _ -W-5- _ _ -…
Magnetic Field Sensors
english
Summary of Contents for BMF 415KW-HA Series
Page 2: ...www balluff com...
Page 3: ...deutsch Betriebsanleitung BMF 415KW HA_ _ _ W 5 _ _...
Page 4: ...www balluff com...
Page 26: ......
Page 27: ...english User s Guide BMF 415KW HA_ _ _ W 5 _ _...
Page 28: ...www balluff com...
Page 50: ......
Page 51: ...fran ais Notice d utilisation BMF 415KW HA_ _ _ W 5 _ _...
Page 52: ...www balluff com...
Page 74: ......
Page 75: ...italiano Manuale d uso BMF 415KW HA_ _ _ W 5 _ _...
Page 76: ...www balluff com...
Page 98: ......
Page 99: ...espa ol Manual de instrucciones BMF 415KW HA_ _ _ W 5 _ _...
Page 100: ...www balluff com...
Page 122: ......
Page 123: ...portugu s Manual de instru es BMF 415KW HA_ _ _ W 5 _ _...
Page 124: ...www balluff com...
Page 146: ......
Page 147: ...BMF 415KW HA_ _ _ W 5 _ _...
Page 148: ...www balluff com...
Page 152: ...6 2 1 BMF 415 2 2 2 3 2 4 2 BMF 415KW HA_ _ _ W 5 _ _...
Page 157: ...www balluff com 11 5 5 1 1 2 3 BMF BMF 5 2 BMF 50 C BMF BMF BMF 415KW HA_ _ _ W 5 _ _...
Page 170: ......
Page 171: ...BMF 415KW HA_ _ _ W 5 _ _...
Page 172: ...www balluff com...
Page 176: ...6 2 1 BMF 415 Balluff 2 2 2 3 2 4 2 BMF 415KW HA_ _ _ W 5 _ _...
Page 181: ...www balluff com 11 5 5 1 1 2 3 BMF BMF 5 2 BMF 50 BMF BMF BMF 415KW HA_ _ _ W 5 _ _...
Page 194: ......
Page 195: ...BMF 415KW HA_ _ _ W 5 _ _...
Page 196: ...www balluff com...
Page 200: ...6 2 1 BMF 415 Balluff 2 2 2 3 2 4 2 BMF 415KW HA_ _ _ W 5 _ _...
Page 205: ...www balluff com 11 5 5 1 1 2 3 BMF BMF 5 2 BMF 50 C BMF BMF BMF 415KW HA_ _ _ W 5 _ _...