background image

 

 

  4

 

N

r./No. 830 513  D/E  

 Ausgabe/Edition 0502;  Änderungen vor

behalten/Subject to modification. 

 Ersetzt Ausgabe/Replaces edition 0501 

Setting 

Two different setting possibilities are available: 
 

− 

Standard setting: Normal calibration procedure (factory 
setting). Only dark-on switching can be implemented 
with this setting. 

 

− 

Fine detection setting: To be used only when the 
standard setting does not achieve the desired results, 
i.e., if the contrast differences are too slight. The fine 
setting can also be used to implement both light-on and 
dark-on switching. 
 

Calibration procedure (Teach-in) 

 
Standard setting: (for dark-on operation only) 
In this configuration the sensor detects objects having a 
lower light intensity than their background.  
 
1. Position the target or mark. 
2. Press the SET button until the bi-color LED turns off. 
3. Release the SET button and wait for the LED to come 

on green. The sensor is ready. The yellow LED comes 
on as soon as the object or mark is detected and the 
output is active. 
 

Fine detection setting (light- or dark-on): 
This mode allows finer contrast differences to be 
distinguished. 
The sensor automatically selects the correct method: 
Light-on for objects or marks which are brighter than the 
background, and dark-on for objects or marks which are 
darker than the background. 
 
1. Position the target or mark. 
2. Hold the SET button down until the bi-color LED goes 

out and then flashes green. Then release the SET 
button. 

3. Place the background in the beam path. 
4. Hold down the SET button again until the bi-color LED 

goes out. The sensor is ready. The yellow LED comes 
on as soon as the object or mark is detected and the 
output is active.  

 

Technical Data 

Optical data 

Operating distance 

19 mm 

±

 2 mm 

Emitter type 

White LED  
(400-700 nm) 

Minimum light spot diameter 

3.5 mm at 19 mm 

 
Electrical data 

Operating voltage U

B

 

10...30 V DC 

Rated operating voltage 

24 V DC 

Ripple 

max. 2 Vpp 

Rated operating current I

100 mA 

Leakage current I

 10 

µ

Rated insulation voltage 

75 V DC 

Switching output 

PNP or NPN,  
N.O. or N.C. 

Voltage drop 

 2 V 

Reverse polarity protected 

yes 

Short circuit protected 

yes 

Switching frequency f 

5 kHz 

Permissible load capacitance 

 1000 nF 

Range setting 

SET button or teach-in 
input 

Protection class 

Light-on/dark-on switching 

Automatic using fine 
calibration 

 
Mechanical data 

Connection type 

M12, 4–pin connector 

Housing material 

GD-Zn, nickel plated 

Active surface material 

Glass (anti-reflective) 

Vibration 

55 Hz, 1 mm amplitude 

Shock 

30 g, 11 ms 

Housing dimensions 

50 x 42.5 x 15 mm 

Weight 80 

 
Time data 

On-delay 

 0.1 ms 

Off-delay 

 0.1 ms 

Ready delay 

< 200 ms 

 
Displays 

Ready/Error 

Bi-color LED (green/red)

Output function 

yellow LED 

 
Ambient data 

Mechanical protection 

IP67 

Permissible ambient light 

max. 10,000 Lux 

Utilization category 

DC 13 

Ambient temperature 

-25 … 55 °C 

 

 

Approvals 

 

Listed 81U2 IND.CONT.EQ. for 
use in the secondary of a class 
2 source of supply

  

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 Balluff 

GmbH 

Schurwaldstrasse 9 
73765 Neuhausen a.d.F. 
Germany 
Phone +49 (0) 71 58/1 73-0 
Fax +49 (0) 71 58/50 10 
E-Mail: [email protected] 

 www.balluff.com 

Reviews: