4
N
r./No. 830 513 D/E
•
Ausgabe/Edition 0502; Änderungen vor
behalten/Subject to modification.
•
Ersetzt Ausgabe/Replaces edition 0501
Setting
Two different setting possibilities are available:
−
Standard setting: Normal calibration procedure (factory
setting). Only dark-on switching can be implemented
with this setting.
−
Fine detection setting: To be used only when the
standard setting does not achieve the desired results,
i.e., if the contrast differences are too slight. The fine
setting can also be used to implement both light-on and
dark-on switching.
Calibration procedure (Teach-in)
Standard setting: (for dark-on operation only)
In this configuration the sensor detects objects having a
lower light intensity than their background.
1. Position the target or mark.
2. Press the SET button until the bi-color LED turns off.
3. Release the SET button and wait for the LED to come
on green. The sensor is ready. The yellow LED comes
on as soon as the object or mark is detected and the
output is active.
Fine detection setting (light- or dark-on):
This mode allows finer contrast differences to be
distinguished.
The sensor automatically selects the correct method:
Light-on for objects or marks which are brighter than the
background, and dark-on for objects or marks which are
darker than the background.
1. Position the target or mark.
2. Hold the SET button down until the bi-color LED goes
out and then flashes green. Then release the SET
button.
3. Place the background in the beam path.
4. Hold down the SET button again until the bi-color LED
goes out. The sensor is ready. The yellow LED comes
on as soon as the object or mark is detected and the
output is active.
Technical Data
Optical data
Operating distance
19 mm
±
2 mm
Emitter type
White LED
(400-700 nm)
Minimum light spot diameter
3.5 mm at 19 mm
Electrical data
Operating voltage U
B
10...30 V DC
Rated operating voltage
24 V DC
Ripple
max. 2 Vpp
Rated operating current I
e
100 mA
Leakage current I
r
≤
10
µ
A
Rated insulation voltage
75 V DC
Switching output
PNP or NPN,
N.O. or N.C.
Voltage drop
≤
2 V
Reverse polarity protected
yes
Short circuit protected
yes
Switching frequency f
5 kHz
Permissible load capacitance
≤
1000 nF
Range setting
SET button or teach-in
input
Protection class
2
Light-on/dark-on switching
Automatic using fine
calibration
Mechanical data
Connection type
M12, 4–pin connector
Housing material
GD-Zn, nickel plated
Active surface material
Glass (anti-reflective)
Vibration
55 Hz, 1 mm amplitude
Shock
30 g, 11 ms
Housing dimensions
50 x 42.5 x 15 mm
Weight 80
g
Time data
On-delay
≤
0.1 ms
Off-delay
≤
0.1 ms
Ready delay
< 200 ms
Displays
Ready/Error
Bi-color LED (green/red)
Output function
yellow LED
Ambient data
Mechanical protection
IP67
Permissible ambient light
max. 10,000 Lux
Utilization category
DC 13
Ambient temperature
-25 … 55 °C
Approvals
Listed 81U2 IND.CONT.EQ. for
use in the secondary of a class
2 source of supply
Balluff
GmbH
Schurwaldstrasse 9
73765 Neuhausen a.d.F.
Germany
Phone +49 (0) 71 58/1 73-0
Fax +49 (0) 71 58/50 10
E-Mail: [email protected]
■
www.balluff.com