Supply voltage V
S
24 V DC ±20%
Residual ripple
≤ 10%
Current draw at 24 V DC
≤ 1 A
X3 - Service interface
RS232
X4 - Application interface
RS232 (BIS U-6020)
Ethernet (BIS U-6027)
Characteristic impedance of the antenna
ports
50 Ω
Adjustable power at the antenna ports
17...30 dBm (50 mW…1 W)
BIS U-6020-053-10_-…
BIS U-6027-054-10_-…
Operating frequency
865.6…867.6 MHz
Maximum permissible radiated power (ERP)
2 watts
ERP
Number of used channels
4
ETSI channels: 4, 7, 10, 13
Channel selection process
Manual (channel assignment plan)
BIS U-6020-059-11_-…
BIS U-6027-060-11_-…
Operating frequency
902…928 MHz
Maximum permissible radiated power (EIRP)
4 watts
EIRP
Number of used channels
52
Channel selection process
Automatic (frequency hopping method)
BIS U-6020-059-12_-…
BIS U-6027-060-12_-…
Operating frequency
920.5…924.5 MHz
Maximum permissible radiated power (ERP)
2 watts
ERP
Number of used channels
16
Channel selection process
Automatic (frequency hopping method)
BIS U-6020-059-13_-…
BIS U-6027-060-13_-…
Operating frequency
915…928 MHz
Maximum permissible radiated power (EIRP)
4 watts
EIRP
Number of used channels
26
Channel selection process
Automatic (frequency hopping method)
Electrical