www.balluff.com
15
Easy Loop Connection System
BIS L-400-... and BIS Z-EL-...
The maximum permissible cable length between the communications module and each indi-
vidual processor is 80 m.
Fig. 1: Cable lengths
The cable length is calculated by adding the sub-sections between the communications module
and the processor, e.g.:
Processor
1
: l = a + b
Processor
2
: l = a + c + d
Processor
3
: l = a + c + e + f
Processor
4
: l = a + c + e + g
l
max
≤
80 m
5
Terminating plug
The following illustrations show various connection options. For example, tees and terminating
plugs can be connected directly to the Communications Module or processors can be con-
nected directly to a tee.
Fig. 15: Tee and terminating plug connected directly to Communications Module, processor directly to tee
or tee directly to tee
Fig. 16: Connecting processors with no terminating plug
1
Communications module
2
Processors on Line 1 (or Line 2)
3
Connection cable BIS Z-5xx-…
4
Tee BKS-S115-TW2-0
5
Terminating plug BKS-S117-R01 on Line 2
Cable lengths
Alternate wiring
options
Getting Started