7
3. Electrical Connections
The terminal screws should be tightened with a slotted screwdriver (blade width 2mm).
3.1. DC Power Supply
The unit accepts DC supply from 18 to 30 V at the terminals 1 and 2. The power consumption
depends on the level of the supply voltage with approx. 100 mA and the additional current
required at the Auxiliary Voltage Output.
All GND terminals are internally interconnected.
3.2. Auxiliary Voltage Output
Terminal 3 and 4 provide an auxiliary output for supply of sensors and encoders.
The output voltage depends on the power supply.
The encoder voltage is approx. 1 V lower than the power supply voltage at terminal 1 and 2
and should be loaded with max. 250 mA.
The auxiliary voltages output is switchable from 24 VDC to 5 VDC.