Balluff BDD 750 S Series User Manual Download Page 32

32 

 

6.  Appendix 

6.1.  Parameter / serial codes 

Menü 

Name 

Serial 

Code 

Min 

Max 

Default 

GENERAL MENU 

DISPLAY FORMAT 

GENERAL MENU 

FACTOR 

-99999999  99999999 

GENERAL MENU 

DIVIDER 

-99999999  99999999 

GENERAL MENU 

ADDITIVE VALUE 

-99999999  99999999 

GENERAL MENU 

DECIMAL POINT 

GENERAL MENU 

SCALE UNITS 

28 

GENERAL MENU 

LINIARIZATION MODE 

GENERAL MENU 

PIN PRESELECTION 

9999 

GENERAL MENU 

PIN PARAMETER 

9999 

GENERAL MENU 

FACTORY SETTINGS 

10 

GENERAL MENU 

10 

11 

GENERAL MENU 

11 

12 

GENERAL MENU 

12 

13 

GENERAL MENU 

13 

14 

SSI PROPERTIES 

MODE 

14 

15 

SSI PROPERTIES 

ENCODER 
RESOLUTION 

15 

10 

32 

25 

16 

SSI PROPERTIES 

BIT PER REVOLUTION 

16 

10 

16 

13 

17 

SSI PROPERTIES 

DATA FORMAT 

17 

18 

SSI PROPERTIES 

BAUD RATE 

18 

19 

SSI PROPERTIES 

HIGH BIT 

19 

32 

25 

20 

SSI PROPERTIES 

LOW BIT 

20 

32 

21 

SSI PROPERTIES 

SET VALUE 

21 

-99999999  99999999 

22 

SSI PROPERTIES 

DIRECTION 

22 

23 

SSI PROPERTIES 

ROUND LOOP VAUE 

23 

99999999 

24 

SSI PROPERTIES 

SAMPLING TIME (S) 

24 

9999 

10 

25 

SSI PROPERTIES 

ERROR BIT 

25 

32 

26 

SSI PROPERTIES 

ERROR POLARITY 

26 

27 

SSI PROPERTIES 

ENCODER SUPPLY 

27 

28 

SSI PROPERTIES 

28 

29 

SSI PROPERTIES 

29 

30 

PRESELECTION VALUES 

PRESELECTION 1 

A0 

-99999999  99999999 

1000 

31 

PRESELECTION VALUES 

PRESELECTION 2 

A1 

-99999999  99999999 

2000 

32 

PRESELECTION VALUES 

PRESELECTION 3 

A2 

-99999999  99999999 

3000 

33 

PRESELECTION VALUES 

PRESELECTION 4 

A3 

-99999999  99999999 

4000 

34 

PRESELECTION 1 MENU 

MODE 1 

A4 

35 

PRESELECTION 1 MENU 

HYSTERESIS 1 

A5 

99999 

36 

PRESELECTION 1 MENU 

PULSE TIME 1 (S) 

A6 

60000 

37 

PRESELECTION 1 MENU 

OUTPUT TARGET 1 

A7 

38 

PRESELECTION 1 MENU 

OUTPUT POLARITY 1 

A8 

39 

PRESELECTION 1 MENU 

OUTPUT LOCK 1 

A9 

40 

PRESELECTION 1 MENU 

START UP DELAY 1 
(S) 

B0 

60000 

41 

PRESELECTION 1 MENU 

EVENT COLOR 1 

B1 

42 

PRESELECTION 1 MENU 

B2 

43 

PRESELECTION 1 MENU 

B3 

Summary of Contents for BDD 750 S Series

Page 1: ...Touch Display BDD 750 _S User s Guide English...

Page 2: ...ownloaded from the Internet at www balluff com All contents included in this manual are protected by the terms of use and copyrights of Balluff GmbH Any reproduction modification usage or publication...

Page 3: ...uch screen 10 4 1 Screen structure for parametrization 10 4 2 Screen structure in operation 11 4 3 Error Message 12 5 Parameter Overview Menu Structure 13 5 1 General Menu 15 5 2 SSI Properties 18 5 3...

Page 4: ...modify the hardware software or operation manual at any time and without prior notice Therefore there might be minor differences between the unit and the descriptions in operation manual The raiser r...

Page 5: ...e ensured Indications about the permissible wire cross sections for wiring are described in the Technical Specifications Before first start up it must be ensured that all connections and wires are fir...

Page 6: ...s are can be configured in the parameter menu The device can be set to one of the following operation modes MASTER The clock for the connected sensor is produced The both clock terminals CLK CLK are c...

Page 7: ...x 100 mA and the additional current required at the Auxiliary Voltage Output All GND terminals are internally interconnected 3 2 Auxiliary Voltage Output Terminal 3 and 4 provide an auxiliary output f...

Page 8: ...8 3 3 SSI Inputs At Terminal 5 6 7 and 8 the connection is available for SSI signals The basic settings must be set in the menu SSI PROPERTIES Wiring for MODE Master Wiring for MODE Slave...

Page 9: ...to receive impulses from electrical impulse sources Notice for mechanical switching contacts When exceptionally mechanical contacts are used please connect an external capacitor between GND and the co...

Page 10: ...er menu via arrow buttons and confirm with OK The menu selection can be terminated with C Parameter selection Select the parameter via arrow buttons and confirm with OK The parameter selection can be...

Page 11: ...ulti turn value Display value for diagnostic purposes raw data no influence on by device functions To switch to the next display press the top of the screen Display with command keys To switch to the...

Page 12: ...ISPLAY VALUE Display value is greater than 99 999 999 ERROR MINIMUM DISPLAY VALUE Display value is less than 99 999 999 ERROR SSI ERROR BIT SET The error bit of the SSI encoder is set In case of error...

Page 13: ...the menu name Menu Parameter GENERAL MENU DISPLAY FORMAT FACTOR DIVIDER ADDITIVE VALUE DECIMAL POINT SCALE UNITS LINEARIZATION MODE PIN PRESELECTION PIN PARAMETER FACTORY SETTINGS Menu Parameter SSI...

Page 14: ...P DELAY 2 EVENT COLOR 2 PRESELECTION 3 MENU MODE 3 HYSTERESIS 3 PULSE TIME 3 OUTPUT TARGET 3 OUTPUT POLARITY 3 OUTPUT LOCK 3 START UP DELAY 3 EVENT COLOR 3 PRESELECTION 4 MENU MODE 4 HYSTERESIS 4 PULS...

Page 15: ...ivider 99999999 Smallest value 1 Default value 99999999 Highest value ADDITIVE VALUE This parameter defines the additive constant 99999999 Smallest value 0 Default value 99999999 Highest value DECIMAL...

Page 16: ...ar 13 bar 14 psi 15 Pa 16 kPa 17 g 18 kg 19 t 20 lb 21 oz 22 ml 23 1 24 cm3 25 m3 26 gal 27 Edit Unit A customized unit with up to 16 digits can be edited using this parameter Pressing the OK button o...

Page 17: ...PRESELECTION VALUE for entering the preselection values Master PIN 6079 This Lock function is only useful in conjunction with active lock function in PIN PARAMETER 0000 No lock 9999 Access after enter...

Page 18: ...bits 10 Smallest value 25 Default value 32 Highest value BIT PER REVOLUTION Bit revolution for singleturn 10 Smallest value 13 Default value 16 Highest value DATA FORMAT Setting the SSI code binary or...

Page 19: ...ommand control input or PC user interface The current SSI position of the encoder is transferred to the parameter SSI offset 99999999 Smallest value 0 Default value 99999999 Highest value DIRECTION De...

Page 20: ...ror bits to be evaluated Review on connected sensor is turned on ERROR POLARITY Defined the polarity of the error bit in the case of an error 0 Bit is low in the case of an error 1 Bit is high in the...

Page 21: ...fault value 99999999 Highest value PRESELECTION 2 Preselection switching point 2 99999999 Smallest value 2000 Default value 99999999 Highest value PRESELECTION 3 Preselection switching point 3 9999999...

Page 22: ...ition is applied Display value PRESELECTION 1 HYSTERESIS 1 OFF Display value PRESELECTION 1 HYSTERESIS 1 OFF 3 RESULT PRES Display value is greater or equal PRESELECTION 1 e g overspeed With HYSTERESI...

Page 23: ...is set when at least one switching condition is true 0 NO No assignment 1 CTRL OUT 1 Switching condition assigned to Ctrl Out 1 2 CTRL OUT 2 Switching condition assigned to Ctrl Out 2 3 CTRL OUT 3 Swi...

Page 24: ...Start Up Delay 3 and 4 have an automatic start up suppression 0 000 No start up suppression 60 000 Start up suppression in seconds EVENT COLOR 1 Event depending change of the display color for the swi...

Page 25: ...the switching condition of preselection 2 See chapter PRESELECTION 1 MENU OUTPUT TARGET 2 Assignment of an output or relay for the switching condition of preselection 2 See chapter PRESELECTION 1 MENU...

Page 26: ...ching condition of preselection 3 See chapter PRESELECTION 1 MENU OUTPUT POLARITY 3 Polarity for the switching condition of preselection 3 See chapter PRESELECTION 1 MENU OUTPUT LOCK 3 Latch for the s...

Page 27: ...eselection 4 See chapter PRESELECTION 1 MENU OUTPUT TARGET 4 Assignment of an output or relay for the switching condition of preselection 4 See chapter PRESELECTION 1 MENU OUTPUT POLARITY 4 Polarity f...

Page 28: ...N 3 d 10 TEACH PRESEL 4 Current display value is stored as PRESELECTION 4 d 11 SCROLL DISPLAY Display switching see display in operation mode d 12 CLEAR LOOP TIME Release all latched switching conditi...

Page 29: ...lling edge INPUT 2 ACTION This parameter defines the function of the input Ctrl In 2 See parameter INPUT 1 ACTION INPUT 2 CONFIG This parameter defines the switching characteristics of the input Ctrl...

Page 30: ...t value 100 Max brightness CONTRAST This parameter defines the viewing angle 0 Viewing angle from top 1 Viewing angle from centre 2 Viewing angle from bottom SCREEN SAVER S This parameter defines the...

Page 31: ...e of the linearization point This value representing the display value which the unit show in the display without linearization 99999999 Smallest X coordinate 0 Default value 99999999 Largest X coordi...

Page 32: ...32 1 21 SSI PROPERTIES SET VALUE 21 99999999 99999999 0 22 SSI PROPERTIES DIRECTION 22 0 1 0 23 SSI PROPERTIES ROUND LOOP VAUE 23 0 99999999 0 24 SSI PROPERTIES SAMPLING TIME S 24 1 9999 10 25 SSI PRO...

Page 33: ...60 PRESELECTION 3 MENU START UP DELAY 3 D0 0 1 0 61 PRESELECTION 3 MENU EVENT COLOR 3 D1 0 3 0 62 PRESELECTION 3 MENU D2 0 0 0 63 PRESELECTION 3 MENU D3 0 0 0 64 PRESELECTION 4 MENU MODE 4 D4 0 9 0 6...

Page 34: ...99 99999999 0 118 LINEARIZATION MENU P5 Y I4 99999999 99999999 0 119 LINEARIZATION MENU P6 X I5 99999999 99999999 0 120 LINEARIZATION MENU P6 Y I6 99999999 99999999 0 121 LINEARIZATION MENU P7 X I7 99...

Page 35: ...9999999 99999999 0 148 LINEARIZATION MENU P20 Y L4 99999999 99999999 0 149 LINEARIZATION MENU P21 X L5 99999999 99999999 0 150 LINEARIZATION MENU P21 Y L6 99999999 99999999 0 151 LINEARIZATION MENU P2...

Page 36: ...to P24 X are used to specify the coordinates on the x axis These are the measuring values that the unit normally would generate according to the actual input signal 9 Now enter the attached values to...

Page 37: ...cture below shows a watergate where the opening is picked up by means of an incremental encoder We would like to display the clearance of the gate d but the existing encoder information is proportiona...

Page 38: ...38 6 3 Reading SSI Value The received data is always filled to 32 bit data length...

Page 39: ...6 4 Internal processing and calculation of SSI data Checking the error bit Data Conversion Grey Code binary Data splitting Bit per revolution and number of revolutions Checking the direction of rotati...

Page 40: ...40 Continuation Internal processing and calculation of SSI data Evaluation of the bit blanking Considering SSI Offset Calculation Display Value...

Page 41: ...41 6 5 Dimensions...

Page 42: ...30 V Max 10 kHz Max 2 mA Ri 15 kOhm 470 pF Relay outputs Number of outputs Configuration AC Switching capacity DC Switching capacity Reaction time 2 potential free changeovers Max 250 VAC 3 A 750 VA M...

Page 43: ...43...

Page 44: ...Drive Florence KY 41042 Phone 859 727 2200 Toll free 1 800 543 8390 Fax 859 727 4823 technicalsupport balluff com CN Service Center China Balluff Shanghai trading Co ltd Room 1006 Pujian Rd 145 Shangh...