background image

Mounting Restrictions

1

www.balluff.com

Electrical Definitions

Cable/terminals

Cable/terminals

NO/NC user selectable

Normally open

Normally closed

Normally closed

NPN (–) sinking

PNP/NPN selectable

DC 3-/4-wire

AC/DC 2-wire

Protection isolated (Protection Class II )

Wire colors, marking

per DIN IEC 60757

BN

brown

BK

black

BU

blue

WH

white

Connector

PNP (+) sourcing

Cable/terminals

To ensure that the sensors are not mechanically destroyed during in-
stallation, make sure that you comply with the following torque figures.

Housing size

Material

Tightening torque

M5×0,5

V2A

3 Nm

M8×1

V2A

15 Nm

M12×1

V2A

40 Nm

M18×1

V2A

60 Nm

M30×1,5

V2A

90 Nm

Manual - Capacitive Sensor BCS

Safety Instructions and Functions and Features

Subject to technical m

odifications is accepted for the accuracy of this inform

ation. ©

Balluf

f GmbH    872033 - 10/2009

You can obtain further information (data sheets, instructions, etc.) via Internet address www.balluff.de

Flush-mount (shielded)
proximity switches

Unshielded
proximity switches

Opposing

installation of 2 sensors

... can be installed with their sensing faces flush to the metal.

The distance between two proximity switches (in row mounting)

must be

2d.

The sensing face must extend

2s

n

from the

two proximity switches must be

2d.

... requires a minimum distance of a

4d

Sensing face

Sensing face

Clear zone

between the sensing faces.

Normally open

(XDC - output)

The sensor closes a circuit to the load when a target is detected
or the sensor is operated. Contacts are open when the sensor
is not operated and when there is no external force on the
actuator.

The sensor opens a circuit to the load when a target is detected
or the sensor is operated. Contacts are closed when the sensor
is not operated and when there is no external force on the actuator.

N.O. (normally open):

N.C. (normally closed):

Switching function

- Please read the product description prior to set-up of the unit. Ensure that the

product is suitable for your application without any restrictions.

- The unit conforms to the relevant regulations and EC directives.

- Improper or non-intended use may lead to malfunctions of the unit or to

unwanted effects in your application.

- That is why installation, electrical connection, set-up, operation and

maintenance of the unit must only be carried out by qualified personnel
authorized by the machine operator.

- The capacitive sensor detects without contact metals, almost all plastics, glass,

ceramics, wood, paper, oils, greases, water and all hydrous materials and
indicates their presence by providing a switched signal.

Connector

metallic installation medium. The distance between

Reviews: