Installation fixture for BMD microwave positioning sensors
Adapting the holder
1.
Disassemble threaded rod (
1
) and cylinder head screw
(
2
).
1
2
2.
Install threaded rod and cylinder head screw into
corresponding hole pair (see page 2). The threaded
rod should extend beyond the front surface by 8 mm.
8
Adjusting the spacers
Both spacers must be adjusted (described here
only for the front spacer). For short strokes (see
page 5) it is sufficient to adjust only the front
spacer.
1.
Unscrew knurled and lock nuts from the threaded rod
(
1
).
2.
Pull threaded rod from the stop (
2
) and insert it into the
desired hole pair of the stop.
1
2
3.
Screw lock and knurled nuts on to the threaded rod
(≈11 mm in knurled nut).
Preparing for installation (continued)
Install support for corresponding cylinder diameter
The support must be fabricated individually
for each cylinder diameter or procured
from a 3-D manufacturer. Construction
data (example: Stuetze_D_80.STL) can be
found at www.balluff.com.
1.
Loosen front adjusting ring (
1
) and slide towards the
front (
2
).
1
2
2.
Clip on support having the corresponding diameter (
3
)
and slide on to the cylinder pin (
4
).
3
4
3.
Slide front ring up to the support (
5
) and tighten down
(
6
).
5
6