BAM OF-VS-004-__-38

Filter set

Condensed Guide

Installation

Make sure the Identsensor BVS ID is not powered.

Step 1: Remove protection cover

 

Remove protection cover by levering out the cover 
using a small screwdriver at the shown spot:

Afterwards, 6 drilling holes for the filter can be seen.

Step 2: Insert O ring

 

Insert the O ring from the filter set and push the o ring 
to the edge.

Never insert the filter without the O ring, otherwise it 
may become permanently jammed.

About this guide

This manual provides important information for the installa-
tion of the following filter sets into the Identsensor BVS ID:

Order 

code

Type

Description

BAM044P

BAM OF-VS-004-
PL-38

Filter for BVS ID, polarization, 
38.3 mm, 18 mm, 2 mm

BAM044R BAM OF-VS-004-

RD-38

Filter for BVS ID, red band-
pass, 38.3 mm, 18 mm, 2 
mm

BAM044T

BAM OF-VS-004-
IR-38

Filter for BVS ID, IR bandpass 
(Daylight Cut), 38.3 mm, 18 
mm, 2 mm

BAM044U BAM OF-VS-004-

DL-38

Filter for BVS ID, Daylight (IR 
Cut), 38.3mm, 18 mm, 2 mm

Scope of filter set delivery

–  AG1 filter Ø38,3/18x2; depending on set

–  AG1 filter ring

–  6 countersunk-head screws DIN 965; M2x5 black

–  O ring 37x1

Following tools are required for proper installation

–  small screwdriver
–  countersunk-head screwdriver (M2)

Safety notes

Activities such as 

installation

connection

 and 

commis-

sioning

 may only be carried out by qualified personnel.

Qualified personnel

 are persons whose technical trai-

ning, knowledge and experience as well as knowledge of 

the relevant regulations allow them to assess the work 

assigned to them, recognize possible hazards and take 

appropriate safety measures.

Storing conditions

 

Store product in original packaging.

 

Observe ambient conditions of −25…+85 °C and a 

relative humidity of ≤ 80 %.