12
english
7
Operating mode (continued)
7.1
Overview of menu structure
7.1.1 Switching mode
Ebene
Display
Function
Section
1
2
1
i n
88888
Analog sensor value (in
digits)
2
t S
88888
3
SP 1
8888
Manually adjusting
switchpoint 1
4
SP2
8888
Manually adjusting
switchpoint 2
5
[
8
]c onf
Submenu:
a
SoA
8888
(switching or
analog)
b
out
8888
Adjusting the switching
power amplifier type/
analog output
c
Mod
8888
d
E t t
8888
e
don
8888
f
dof
8888
6
[
8
]di SP
Submenu:
g
F W
88888
Display of software
version
h
HW
88888
Display of hardware
version
i
L uM
8888
j
180
8888
Display text rotation
(0/180°)
k
VaL
8888
Dampening rate display
in RUN mode
7
E nd
8888
Tab. 7-2: Menu structure: Switching mode
7.1.2 Analog mode
Ebene
Display
Function
Section
1
2
1
Nno
8888
Analog sensor value (in
digits)
2
t A
88888
3
[
8
]c onf
Submenu:
a
SoA
8888
(switching or
analog)
b
SA
88888
Adjusting the switching
power amplifier type/
analog output
4
[
8
]di SP
Submenu:
g
F W
88888
Display of software
version
h
HW
88888
Display of hardware
version
i
L uM
8888
j
180
8888
Display text rotation
(0/180°)
k
VaL
8888
Dampening rate display
in RUN mode
5
E nd
8888
Tab. 7-3: Menu structure: Analog mode
7.2
Analog sensor value (in digits)
i n
/
Ano
Indicates a value dependent on the sensor, distance
(relative measurement), or dampening.
Display range: 0…4095
BAE SA-CS-026-YP-BP02 / BAE SA-CS-026-YP-BP00,3-GS04
Comfort Sensor Amplifier