10
english
6.1
Startup
DANGER
Uncontrolled system movement
When starting up, if the sensor amplifier is part of a
closed loop system whose parameters have not yet
been set, the system may perform uncontrolled move-
ments. This could result in personal injury and equip-
ment damage.
►
Persons must keep away from the system’s hazar-
dous zones.
►
Startup must be performed only by trained technical
personnel.
►
Observe the safety instructions of the equipment or
system manufacturer.
1.
Check connections for tightness and correct polarity.
Replace damaged connections.
2.
Turn on the system.
3.
Check measured values and adjustable parameters
and readjust the sensor amplifier if necessary. Check
spacing over the entire measuring range.
Check for the correct values, especially after
replacing the sensor amplifier or after repair by the
manufacturer.
6.2
Quick startup
To adjust the sensor to the application, generally only the
switching stage (N.C. or N.O.) must be set and the switch-
on point taught in.
All other settings are returned to factory settings.
Configuring the power amplifier
1.
Press and hold the
button for at least 8 s.
⇒
The remaining time is shown in the display (in
seconds).
2.
Configure the power amplifier with the
and
buttons.
Display
Configuration
PPno
Push-Pull power amplifier: N.O.
PPnc
Push-pull power amplifier: N.C.
3.
Press the
button.
Teaching in the switchpoint
1.
Place the sensor in the desired detection state.
a.
Distance to the object
BAE
A
b.
Sensor surface covering
BAE
3.
Teach in the detection state with the
button.
⇒
The process can be repeated; switching hysteresis
is fixed.
4.
End startup mode using the
button.
⇒
All settings are saved; the display indicates
run
and
the sensor dampening rate in digits.
6.3
Operating notes
– Regularly check function of the sensor amplifier and all
associated components.
– Take the sensor amplifier out of service whenever there
is a malfunction.
– Secure the system against unauthorized use.
– Check fasteners and retighten if needed.
6.4
Maintenance
The product is maintenance-free.
Object
Sensor
button
A = max.
detection state
Fill level
Sensor
button
6
Startup and operation
BAE SA-CS-026-YP-BP02 / BAE SA-CS-026-YP-BP00,3-GS04
Comfort Sensor Amplifier