Balluff BAE PS-XA-1S-24-200-104 Installation Manual Download Page 7

www.balluff.com

1

English

EU Directive 2004/108/EC (EMC Directive) 

Low Voltage Directive 2006/95/EC 

Product standard EN 61204-3. Safety of Information Technology Equipment EN 60950

Safety instructions

Before commissioning, read the user's guide 

carefully!

These devices must not be used in applications 

in which the safety of persons is dependent on 

the function of the device (not a safety compo-

nent acc. to EU Machinery Directive).

DANGER

 from high voltages! 

Contact with unprotected conductors and 

components can result in a fatal electric shock 

or severe burns. 

Before starting work on the device, interrupt the 

power supply and secure against restart. Do not 

insert foreign objects into the device. Keep 

away from fire.

Installation and commissioning

 must only be perfor-

med by trained specialist personnel. 

The 

operator

 is responsible for ensuring that local safety 

regulations are observed.
In particular, the operator must take measures to ensure 
that a defect in the device will not result in hazards to 
persons or equipment.
If defects and persistent faults occur in the  
switching power supply, take it out of service and secure 
against unauthorized use.

Download of the user's guide

The user's guide can also be found on the internet at 

www.balluff.com

.

Scope

This guide is valid for the following devices:

 

– BAE PS-XA-1S-24-200-104 (ordering code BAE00M3)

Installation

Attention! 

Connect the device to mains in accordance with 

local regulations and standards. 

Do not cover the device! Ensure that there is 

sufficient space around the device to allow for 

cooling, otherwise the device may shut down 

due to overheating. The service life of the device 

is shortened once it is operated for a longer 

period of time in an overheated state. The stress 

level indicator signals inadequate cooling. 

The housing may become hot during operation!

Electrical connections

 

– Data for permissible loads, see table "Technical data".

 

– Only use commercial cables suitable for the specified 

current and voltage values.

 

– For flexible cables, make sure that all strands are 

secured in the terminal.

 

– Make sure the polarity at the output is correct.

 

– Always switch the power off before connecting or 

disconnecting plug connections.

 

– If necessary, a manually controlled element for isolating 

the mains power supply must be used.

 

– Device and power cables must be fused correctly.

 

– The unsecured ground conductor must be connected 

to GND (insulation class 1).

 

– The secondary side is not grounded. If necessary, the 

plus or minus terminal can be grounded.

 

– Do not modify the installation while the device is opera-

ting! The same applies for the secondary side. Danger 
from electric arcing and deadly electric shocks. 

Intended use

This device is a primary switched-mode power supply for 
integration in control panel installations or integral applica-
tions where access to the power supply is restricted 
(contact protection). The device is suitable for contamina-
tion class 2. 

Modifications to the device or non-approved use are not 
permitted and will result in loss of warranty and void any 
liability claims against the manufacturer.

Switching power supplies IO-Link ready

MAN-SHG BAE PS-XA-1S-24-200-104

Summary of Contents for BAE PS-XA-1S-24-200-104

Page 1: ...as Ger t nicht abdecken F r die K hlung ausreichenden Raum um das Ger t herum vorsehen sonst kann das Ger t durch berhi tzung abgeschaltet werden Die Lebensdauer des Ger ts sinkt sobald es l nger im b...

Page 2: ...Lebensdauer beginnt bei 15 Jahren und nimmt ent sprechend des Stressniveaus und der Belastung ab Load Level Anzeige Belastungsniveau Die LEDs signalisieren verz gerungsfrei die aktuelle Auslas tung de...

Page 3: ...rm Der Kontakt schlie t sobald die Ausgangsspannung au erhalb von 21 V 28 5 V DC liegt z B wenn ein Kurzschluss ansteht Kontakt Stresslevel Der Kontakt schlie t sobald die Stresslevel LED auf rot scha...

Page 4: ...ailable 0x8012 Subindex not available 0x8023 Access Denied 0x8030 Parameter Value out of Range 0x8033 Paremeter length overrun 0x8034 Parameter length underrun 0x8035 Function not available IO Link In...

Page 5: ...t 1 R W 2 Process Data Over load 0 1 A 0x3D 0x03 BDC1 Hysteresis R W 2 0 0xFFFF 0 1 A 0x3E 0x01 BDC2 SetPoint 1 R W 2 Process Data Over voltage 0 1 V 0x3F 0x03 BDC2 Hysteresis R W 2 0 0xFFFF 0 1 V 0x5...

Page 6: ...auigkeit 1 0 Spannungsregelung 0 5 Lastregelung 0 5 Lasttyp resistive capacitive Technische Daten Werte gemessen bei 25 C und Volllast Mechanische Daten Werkstoff Geh use Metall Gewicht 1 1 kg Abmessu...

Page 7: ...he device Ensure that there is sufficient space around the device to allow for cooling otherwise the device may shut down due to overheating The service life of the device is shortened once it is oper...

Page 8: ...e gently to verify that it has been latched Removal Switch off the power supply and disconnect the sys tem from mains Disconnect all connectors from the power supply Slide the latch guard down unlatch...

Page 9: ...ntact closes as soon as the output voltage lies between 21 V and 28 5 V DC e g when there is a short circuit Stresslevel contact The contact closes as soon as the Stresslevel LED turns red Connections...

Page 10: ...vailable 0x8012 Subindex not available 0x8023 Access Denied 0x8030 Parameter Value out of Range 0x8033 Paremeter length overrun 0x8034 Parameter length underrun 0x8035 Function not available IO Link I...

Page 11: ...1 BDC1 SetPoint 1 R W 2 Process Data Over load 0 1 A 0x3D 0x03 BDC1 Hysteresis R W 2 0 0xFFFF 0 1 A 0x3E 0x01 BDC2 SetPoint 1 R W 2 Process Data Over voltage 0 1 V 0x3F 0x03 BDC2 Hysteresis R W 2 0 0x...

Page 12: ...0 5 Load type resistive capacitive Technical data Values measured at 25 C and full load Mechanical data Housing material Metal Weight 1 1 kg Dimensions W x H x D mm 73 5 x 127 x 137 Terminal 0 25 mm 4...

Page 13: ...Ne pas couvrir le dispositif Afin d assurer le refroidissement d un espace suffisant pour l appareil celui ci peut galement tre arr t via une surchauffe La dur e de vie du dispositif diminue d s lors...

Page 14: ...il D montage D sactiver l alimentation lectrique et d brancher le syst me du r seau d alimentation D brancher l ensemble des connecteurs du bloc d alimentation Pousser la protection de verrouillage ve...

Page 15: ...sortie se trouve en dehors de 21 V 28 5 V DC p ex en cas de court cir cuit Contact Stresslevel niveau de charge Le contact se ferme d s que la LED Stresslevel commute en rouge Connexions Fig 2 Connex...

Page 16: ...Error Codes Error Code Description 0x8011 Index not available 0x8012 Subindex not available 0x8023 Access Denied 0x8030 Parameter Value out of Range 0x8033 Paremeter length overrun 0x8034 Parameter le...

Page 17: ...R 1 0 4 0x3C 0x01 BDC1 SetPoint 1 R W 2 Process Data Over load 0 1 A 0x3D 0x03 BDC1 Hysteresis R W 2 0 0xFFFF 0 1 A 0x3E 0x01 BDC2 SetPoint 1 R W 2 Process Data Over voltage 0 1 V 0x3F 0x03 BDC2 Hyste...

Page 18: ...Courant de sortie nominal 20 A Puissance de sortie 480 W Plage de r glage 22 28 V DC Pr cision de la tension de sortie 1 0 R gulation de tension 0 5 R gulation de charge 0 5 Type de charge resistive c...

Page 19: ...er consentire il raffreddamento dell apparecchio assicurarsi che esso abbia spazio sufficiente intorno a s in caso contrario il surriscaldamento potr cau sarne lo spegnimento La durata dell apparec ch...

Page 20: ...arecchio Smontaggio Staccare la corrente e separare il sistema dalla rete di alimentazione Separare tutti i connettori dall alimentatore Spingere verso il basso la protezione del bloccaggio sbloccare...

Page 21: ...Alarm Il contatto chiude non appena la tensione in uscita oltre 21 V 28 5 V CC ad es in presenza di cortocircuito Contatto Stresslevel Il contatto chiude non appena il LED Stresslevel commuta su luce...

Page 22: ...4 4 Error High stress level 0xB005 0x1805 4 Warning Fast aging 0xB006 0x1806 4 Warning Over Tempera ture 0xB007 0x1807 4 Warning Over load 0xB008 0x1808 4 Warning Informazioni generali sull apparecchi...

Page 23: ...3C 0x01 BDC1 SetPoint 1 R W 2 Process Data Over load 0 1 A 0x3D 0x03 BDC1 Hysteresis R W 2 0 0xFFFF 0 1 A 0x3E 0x01 BDC2 SetPoint 1 R W 2 Process Data Over voltage 0 1 V 0x3F 0x03 BDC2 Hysteresis R W...

Page 24: ...Campo di regolazione 22 28 V DC Precisione di uscita 1 0 Regolazione di tensione 0 5 Regolazione del carico 0 5 Tipo di carico resistive capacitive Dati meccanici Materiale della custodia Metal Peso 1...

Page 25: ...cio alrededor del aparato para la refrigeraci n para evitar que el aparato pueda desconectarse debido a un calentamiento excesivo La vida til del aparato se reduce si funciona durante un tiempo prolon...

Page 26: ...riente y separar el sistema de la red de alimentaci n Separar todos los conectores de la fuente de alimentaci n Empujar hacia abajo la protecci n de bloqueo des bloquear Elevar ligeramente el borde fr...

Page 27: ...nto la tensi n de salida se encuentra fuera de 21 V 28 5 V CC p ej cuando se produce un cortocircuito Contacto nivel de estr s El contacto se cierra en cuanto el nivel de estr s del LED conmuta a rojo...

Page 28: ...es Definition Event Codes IO Link 1 1 Event Codes IO Link 1 0 Device status Type No malfunction 0x0000 0x0000 0 Notifica tion General mal function Unknown error 0x1000 0x1000 4 Error Process variable...

Page 29: ...0x3C 0x01 BDC1 SetPoint 1 R W 2 Process Data Over load 0 1 A 0x3D 0x03 BDC1 Hysteresis R W 2 0 0xFFFF 0 1 A 0x3E 0x01 BDC2 SetPoint 1 R W 2 Process Data Over voltage 0 1 V 0x3F 0x03 BDC2 Hysteresis R...

Page 30: ...ajuste 22 28 V DC Precisi n de salida 1 0 Regulaci n de tensi n 0 5 Regulaci n de carga 0 5 Tipo de carga resistive capacitive Datos mec nicos Material de la carcasa Metal Peso 1 1 kg Dimensiones B x...

Reviews: