26
5.REFRIGERANT SYSTEM DIAGRAM
MAX. REFRIGERANT PIPING LENGTH
Piping size O.D : mm
Length of connecting pipe : m
Modles
Refrigerant Piping
Max. Length : m
A
Gas
Liquid
Indoor unit
Outdoor unit
KFR-4801GWE
15
12.7
6.35
KF-5002GWE
15
12.7
6.35
MAX. HEIGHT DIFFERENCE
Indoor
unit
`
Refrigerant piping
Max. length
Max. Height
A
difference 7m
Outdoor unit
ADDITIONAL; REFRIGERANT CHARGE(R-22 : g)
Refrigerant piping length (one way)
Modles
Outdoor unit precharged
(up to 7m)
7m
10m
15m
KFR-4801GWE
1750
0
150
400
KF-5002GWE
1850
0
150
400
Canculation :Xg=50g/m * (A-7)m
Summary of Contents for KF-25GWE
Page 14: ......
Page 15: ......
Page 16: ......
Page 17: ......
Page 22: ......
Page 23: ......
Page 24: ......
Page 25: ......
Page 53: ...12 PARTS LIST KFR 33GE 52 KF R 25GE KFR 2501GE KFR 3301GE KF 34GE KFR 3201GE...
Page 54: ...12 PARTS LIST KFR 33WE KF R 25WE KFR 2501WE KFR 3301WE KF 34WE KFR 3201WE 53...
Page 55: ...12 PARTS LIST KF 5002WE 54...