background image

REPLACING THE MICROSWITCH 

Take off the front and rear plates. 
Take off the wires for the micro switch. 
Take off the lever. 
Take off the micro switch. 
Replace the defect micro switch with a new one. 
Re-assemble in the opposite steps. 
 
 
 
 
 
 
 

REPLACING THE CONTROL PANEL 

Take off the front & rear plates. 
Take off the control panel and its wires. 
Replace with a new one. 
Re-install in the opposite steps. 
 
 
 
 
 
 

 

 

 
After-Check 
Please do the following checks after repair: 
 
Make sure the working current is correct. 
Make sure the wire distribution is correct according to the supplied diagram. 
Make sure the pipes, tubes are in the right position, do not hit with the other parts. 
Make sure the insulation resistance between the plug and grounding is over 2M

Make sure the whole cooling system is of no leakage. 
Make sure the fan operates normally and does not hit the other parts. 
Make sure the compressor can operate normally, without abnormal noise. 
Set the machine to max. cooling and high ventilation, after 30 minutes, put your hand on the evaporator to 
check it is making the cooling or not. 
Measure the temperature at the air inlet and outlet, make sure the temperature difference is over 10

o

C. 

Make sure the water tray, water pipe inside the machine are of no leakage and well-installed.   
 

Summary of Contents for AC-N006R

Page 1: ...Service Manual AC N006R AC N006RH AC T006R AC T006RH...

Page 2: ...working range of the machine Close the windows doors Please check Is the current power consumption decreasing Is the suction pressure of the machine too low Is the temperature of the discharging tube...

Page 3: ...bes Motor doesn t work Wires problem Loose terminal connection Motor breaks down Motor capacitor breaks down The fan blade is stuck Check and replace Check and fasten Check and replace Check and repla...

Page 4: ...within 3g Re switch the unit after the temperature drops down Discharge temperature is too high Refrigerant is too less or has been leaked Condenser too dusty Air return of the condenser is blocked A...

Page 5: ...ssories wires screws in the opposite steps REPLACING THE OVERLOAD PROTECTOR OF THE COMPRESSOR Take off the accessories for the overload protector Take off the defect overload protector and replace it...

Page 6: ...l in the opposite steps REPLACING THE DOWN MOTOR CAPACITOR FOR CONDENSOR Take off the rear plate of the machine Take off the wires for the capacitor then take off the capacitor Replace with a new one...

Page 7: ...the motor and fan blade of the evaporator Replacing the defect fan blade Re install in the opposite steps REPLACING THE PUMP MOTOR Take off the front rear plates Unfasten the wires for the pump motor...

Page 8: ...ccording to the supplied diagram Make sure the pipes tubes are in the right position do not hit with the other parts Make sure the insulation resistance between the plug and grounding is over 2M Make...