PROBLEM 

POSSIBLE CAUSE 

SOLUTION 

Compressor works but 
the fan doesn’t. 

Bad connection of the wires. 
Fan motor breaks down. 
Fan motor capacitor breaks down. 
P.C. board breaks down. 
Fan blade is stuck. 
 

Check and reconnect or replace. 
Check and replace. 
Check and replace. 
Check and replace. 
Fix it. 

Big noise 

Screws/nuts of the fan for evaporator/ 
condenser come loose. 
Screws/nuts of the compressor come loose.
Fan blade is blocked by something. 

Check and fasten. 
 
Check and fasten. 
 
Remove the blockade. 

Big vibration 

Screws/nuts of the compressor come loose.
Fan of the evaporator or condenser does 
not fix well or is deformed. 
The metal tubes inside the machine hit the 
other parts. 

Check and fasten. 
 
Check and replace. 
 
Adjust the position of the tubes. 

Motor doesn’t work. 

Wires problem. 
Loose terminal connection. 
Motor breaks down. 
Motor capacitor breaks down. 
The fan blade is stuck. 

Check and replace. 
Check and fasten. 
Check and replace. 
Check and replace. 
Fix it. 

Auto-drainage system 
doesn’t work.   

Wires problem. 
Pump motor breaks down. 
Bad installation of the water pump. 
Micro switch breaks down. 

Check and replace. 
Check and replace. 
Re-install. 
Check and replace. 

Suction pressure is too 
low while the suction 
temperature is too high. 

Blocked capillary 
Blocked evaporator. 
Blocked refrigerant filter. 
Insufficient refrigerant or the refrigerant 
has been leaked. 
 

Replace the capillary. 
Use high pressure N

2

 to clean the 

evaporator or replace it. 
Replace the refrigerant filter. 
Release the remained refrigerant, 
vacuum the unit (at least over 
755mmHg).    Recharge the unit. For 
correct refrigerant amount, please refer 
to the rating label at the back of the 
unit. The deviation should be within 3g.

Summary of Contents for AC-N006R

Page 1: ...Service Manual AC N006R AC N006RH AC T006R AC T006RH...

Page 2: ...working range of the machine Close the windows doors Please check Is the current power consumption decreasing Is the suction pressure of the machine too low Is the temperature of the discharging tube...

Page 3: ...bes Motor doesn t work Wires problem Loose terminal connection Motor breaks down Motor capacitor breaks down The fan blade is stuck Check and replace Check and fasten Check and replace Check and repla...

Page 4: ...within 3g Re switch the unit after the temperature drops down Discharge temperature is too high Refrigerant is too less or has been leaked Condenser too dusty Air return of the condenser is blocked A...

Page 5: ...ssories wires screws in the opposite steps REPLACING THE OVERLOAD PROTECTOR OF THE COMPRESSOR Take off the accessories for the overload protector Take off the defect overload protector and replace it...

Page 6: ...l in the opposite steps REPLACING THE DOWN MOTOR CAPACITOR FOR CONDENSOR Take off the rear plate of the machine Take off the wires for the capacitor then take off the capacitor Replace with a new one...

Page 7: ...the motor and fan blade of the evaporator Replacing the defect fan blade Re install in the opposite steps REPLACING THE PUMP MOTOR Take off the front rear plates Unfasten the wires for the pump motor...

Page 8: ...ccording to the supplied diagram Make sure the pipes tubes are in the right position do not hit with the other parts Make sure the insulation resistance between the plug and grounding is over 2M Make...

Reviews: