LX1553-5 FEATURES
5-6
Lx1553-5
User’s
Manual
Format
A 1000
pps
B 100
pps
Modulation Frequency
0
1
Pulse width coded
Amplitude modulated
Frequency/Resolution
0
2
3
4
5
No carrier/index count interval
1 kHz/1 ms (B only)
10 kHz/.1 ms
100 kHz/10 ms
1 MHz/1 ms
Coded Expressions
0, 1, 2, 3
Slave: Uses only BCD field (input)
Table 5.3—Input IRIG formats used by Lx1553-5
Format
A 1000
pps
B 100
pps
Modulation Frequency
0
Pulse width coded
Frequency/Resolution
0
No carrier/index count interval
Coded Expressions
2
Master: BCD (output)
Table 5.4—Output IRIG formats used by Lx1553-5
Input impedance (min)
12 k
Ω
Input level
-7.5V to 12.5V volts
Input level threshold
API Controlled (0V-5V)
Output level
0 to 3 volts
Output drive capability
20 mA
Table 5.5—Electrical characteristics of Lx1553-5 IRIG signals
For information on configuring and using the IRIG timer consult the BTIDriver
API programming manuals.