OmniCare EVC System
Installation & Commissioning Manual
OmniCare issue 1
21
C
O
M
M
U
N
I
C
A
T
I O N S
Circuit Cabling for Short Circuits, Open Circuits, shorts to
Ground, and Correct Phasing of all conductors.
2. If not already fitted, mount the supplied back box at each
Remote Unit location.
3. At the rear of the Remote Unit remove the screw (item B in
Figure 3.2) to release the bracket retaining the blue
termination block.
Figure 3.2 — Rear View of BVOCECP Remote Unit
4. Terminate all cables at the termination block according to
the system designer's specifications and the diagram on the
Remote Unit rear panel. It is important that each conductor
is correctly identified before being terminated.
A
Cable Termination Block under removable bracket
B
Removable Bracket securing screw
C
J1 for controlling external equipment (NO or NC)
D
SW1.1 and 1.2 must be set to OFF
E
Option Jumpers - refer to Table 3.1 for details
F
Speaker volume control
N
OTE
: As an aid, the Blue Block is also labelled with the connection
details to indicate where each conductor should be terminated.