BASIC

STATUS

F1601T1

BACK

CONTROL TYPE

V/F Control

MOTOR CONTROL

LEVEL 1 BLOCKS

LEVEL 2 BLOCKS

LEVEL 3 BLOCKS

MODIFIED PARAMS

LINEAR LIST

EV. LOG

E

C

A

R

T

S

U

T

A

T

S

       LOW INITIAL BUS

0

4-Jul-06   09:35:00

LOCAL

STOP

EV. LOG

0.00r

MAIN

OPTION B OARDS

OPTION 1

 Ethernet

OPTION 2

None

FEEDBACK

None

DIAG

STOP

LOCAL

PROG

KEYPAD SETUP

DIAG

F1313T1

BACK

KEYPAD CONTRAST

50%

Status

Basic

Params

Advanced

Prog

Event Log

Diagnotics

Display

Options

See other side for Control Connections

 

K

C

A

B

G

A

I

D

STATUS

BASIC PARAMS

ADVANCED PROG

EVENT LOG

DIAGNOSTICS

DISPLAY  OPTIONS

 

Keypad Display

 

- Displays status information during 

Local or Remote operation. It also displays information 

during parameter setup and fault or Diagnostic 

Information.

Display Diagnostics

 - 

I/O Status

I/O Function configuration

Modified parameters

Control Operation Data

Custom Units

Fault Display - 10 Faults with Time stamp

F1 - Alternates or “Toggles” between last two menu 

choices or function indicated by text displayed directly 

above key.

F2 - Clear faults or undo parameter edit changes or 

function indicated by text displayed directly above key.

p

 (Up Arrow),  

q

 (Down Arrow)

t

 (Left Arrow),  

u

 (Right Arrow)

Moves cursor to select menu choices.

ENTER

 - Press ENTER to save parameter value changes. 

In the display mode the ENTER key is used to directly 

set the local speed reference. It is also used to select 

other operations when prompted by the keypad display.

MENU

 - Selects the Menu display.

The following menu items are shown: Status, 

Diagnostics, Fault Log, Advanced Programming, and 

Basic Params.

LOCAL REMOTE 

- Changes between local and remote 

modes.

HELP

 - Provides help at each display screen, setup 

parameter and fault. Press to view/close help 

information.

REV

 - When pressed, initiates a reverse direction run 

command.

JOG

 - Initiates Jog mode when pressed. Press  

FWD or REV for motion.  Only active in local mode.

FWD

 - When pressed, initiates a forward direction run 

command.

STOP

 - Initiates a stop command.

MS764

9/09

WARNING: Be sure that you are completely familiar with the safe operation of this equipment. Refer to MN764.

This equipment may be connected to other machines that have rotating parts or parts that are controlled by this equipment.  

Improper use can cause serious or fatal injury.  Only qualified personnel should attempt the start-up procedure or to operate or 

troubleshoot this equipment.

VS1SP

Open Vector Drive

3/4 to 450 hp

Quick Start Guide

Wiring / Power Up
Parameter Setting

Open Loop (Encoderless) Vector

V/Hz Inverter

Indicator Light

 -

(On when indicated Key is active)

FWD key with green light indicator.

REV key with green light indicator.

JOG key with green light indicator.

STOP key with red light indicator.

F1601T1   CONTROL TYPE V/F Control

F2401T1  MOTOR RATED VOLT  

F2402T1  MOTOR RATED AMPS  

F2405T1  MOTOR MAG AMPS  

F2403T1  MOTOR RATED SPD 

F2404T1  MOTOR RATED FREQ 

F2413T1  CALC MOTOR MODEL 

F2901T1  ANA OFFSET TRIM  

F1401T1  OPERATING MODE 

F1101T1  ACCEL TIME 1

F1104T1  DECEL TIME 1 

F2002T1  MIN OUTPUT SPEED 

F2003T1  MAX OUTPUT SPEED

F1601T1   CONTROL TYPE Open Vector

F2401T1  MOTOR RATED VOLT  

F2402T1  MOTOR RATED AMPS  

F2405T1  MOTOR MAG AMPS  

F2403T1  MOTOR RATED SPD 

F2404T1  MOTOR RATED FREQ 

F2901T1  ANA OFFSET TRIM  

F2902T1  ONE-STEP TUNING

F1401T1  OPERATING MODE 

F1101T1  ACCEL TIME 1

F1104T1  DECEL TIME 1 

F2002T1  MIN OUTPUT SPEED 

F2003T1  MAX OUTPUT SPEED

Reviews: