Operation 4-5
MN2488
Engine Controller
The Engine Control panel is shown in Figure 4-5. The control is used to start and stop the
engine and indicate fault conditions, automatically shutting down the engine and indicating the
failure by LED. An integral anti
−
tamper engine hours counter and LCD display is also provided.
Figure 4-5 Engine Controller Panel
STOP
Position
RUN
Position
Engine Hours Display
Over Speed Shutdown
Aux Input Active
Low Oil Pressure Shutdown
Alternator Charge Failure Warning
High Coolant Temp Shutdown
Pre−Heat Switch
Engine Start Switch
Key
Switch
Note: Operation of any alarm (Low Oil Pressure, High Engine Temperature, Aux Input or
Overspeed) will cause the run output to de
−
energize and stop engine operation:
Panel Description
Over Speed
On indicates engine speed exceeds the pre
−
set trip (14% above
nominal frequency) and shutdown is initiated. Overspeed is not
delayed, it is an immediate shutdown.
Aux Input Active
On indicates the auxiliary input is active preventing the start of the
generator. If generator is running, if the auxiliary input is energized an
immediate shutdown will occur. (Optional connections).
Low Oil Pressure
On displays low oil pressure condition. After the Safety On timer has
expired, a shutdown will occur.
Alternator Charge Failure On displays low battery voltage condition at the battery.
High Coolant Temp
On indicates engine coolant temperature has exceeded the high engine
temperature switch setting, after the Safety On timer has expired, a
shutdown will occur.
Pre
−
Heat
Pressing the pre
−
heat button will energize the engine glow plugs.
Releasing the button will de
−
energize the output to the glow plugs.
Engine Hours Display Displays total hours of engine operation. Only displayed in Run Position
of Key switch.
Engine Start Switch
Press to energize the Fuel Solenoid and the Starter Motor output.
The switch should be pressed for the duration of the crank period. The
starter motor is disengaged and locked out at 20 Hz measured from the
Alternator output.
Key Switch
Stop Position de
−
energizes the Fuel Solenoid, bringing the generator to
a stop.
Run Position applies power to the control module and allows Start/Run
operation.
Note: The Safety On time (used for delayed alarms) is preset to 12 seconds.
Summary of Contents for POW'R LITE PL6000K
Page 1: ...POW R LITE PL6000K Portable Light Tower Installation Operating Manual 9 06 MN2488 ...
Page 4: ...ii Table of Contents MN2488 ...
Page 12: ...2 2 General Information MN2488 ...
Page 17: ...Receiving Installation 3 5 MN2488 Figure 3 3 Trailer Harness ...
Page 18: ...3 6 Receiving Installation MN2488 ...
Page 30: ...5 4 Troubleshooting and Maintenance MN2488 Figure 5 7 Flood Light Mast Wiring ...
Page 31: ...Troubleshooting and Maintenance 5 5 MN2488 Figure 5 8 Engine and Control Wiring ...
Page 32: ...5 6 Troubleshooting and Maintenance MN2488 ...
Page 33: ...Baldor District Offices ...