Baldor PG 6000 Installation & Operating Manual Download Page 6

1‐2 Product Safety Information

MN2418

Precaution Statements Used In This Manual

There are three classifications of precautionary statements used in this manual.  The most critical
is a 

WARNING

 statement, then the 

Caution

 statement and the least critical is the Note

statement.  The usage of each statement is as follows:

WARNING: Indicates a potentially hazardous situation which, if not avoided, could result in injury or

death.

Caution:

Indicates a potentially hazardous situation which, if not avoided, could result in damage to
property.

Note:

Additional information that is not critical to the installation or operation.

IMPORTANT SAFETY INSTRUCTIONS

SAVE THESE INSTRUCTIONS -  

This manual contains important instructions for the generator that should

be followed during installation, operation and maintenance of the generator.
For ease of reading, the Warning statements are divided into four categories: Operation, Burn, Installation,
and Maintenance.

Operation
WARNING: Gasoline and diesel fuel are flammable and can cause fire, explosions, injury or death.  For

storage or refueling handle fuel with care and only in clean, approved, properly marked safety
fuel containers.

WARNING: Do not overfill the fuel tank.  Only fill the tank to within 

1

/

2

,

 of the top of the tank to allow

space for fuel expansion.  Overfilling of tank may cause fuel to spill out onto engine and
cause fire or explosion.

WARNING: Clean up fuel spills by wiping completely dry before starting engine. Gasoline and diesel fuel

are flammable and can cause fire, explosions, injury or death.

WARNING: Make sure the fuel cap is completely and securely closed after refueling to prevent spillage.

Gasoline and diesel fuel are flammable and can cause fire, explosions, injury or death.

WARNING: Never operate this generator in a manner other than as described in this manual.  Operation

in any manner not described in this manual should be considered unsafe and should not be
attempted.  Never start the engine unless you have first verified that the installation and
operation of the generator are as described in this manual.

WARNING: Be sure that you are completely familiar with the safe operation of this equipment.  This

equipment may be connected to other machines that have rotating parts or parts that are
controlled by this equipment.  Improper use can cause serious or fatal injury.

WARNING: Exhaust fumes/gases are extremely dangerous and can cause severe illness or death.  Never

breath exhaust fumes produced by a running engine.  Only run the engine outdoors where
ventilation is plentiful.  Exhaust gases contain carbon monoxide, a colorless, odorless and
extremely dangerous gas that can cause unconsciousness or death.  Symptoms of carbon
monoxide poisoning include: dizziness, nausea, headaches, sleepiness, vomiting or
incoherence.  If you or anyone else experiences these symptoms, get out into fresh air
immediately.  Stop the engine and do not restart the engine until it has been inspected and if
necessary repaired or reinstalled in a well ventilated area.

WARNING: Hot exhaust gasses must never be directed toward anything that may catch fire or explode.
WARNING: This generator must not be used on or near any forest covered, brush covered, or grass

covered land unless the engine's exhaust system is equipped with a spark arrestor.  The
spark arrestor must be maintained in effective working order by the operator.

WARNING: Some parts of this generator rotate during operation.  Rotating parts can present extreme

danger if clothing or body extremities are caught by the rotating part and can cause serious
or fatal injury.  Never touch a part of the generator until the engine has been stopped and all
rotating parts are completely stopped.  Also, disconnect the spark plug wires and battery
connection to prevent accidental engine rotation during servicing.

WARNING: Never move a generator set that is running.  Loads should be connected and position secure

before starting the engine.  Hazards are caused by moving a generator set that is running.

Continued on next page.

Summary of Contents for PG 6000

Page 1: ...PG 6000 Generator Installation Operating Manual 8 06 MN2418...

Page 2: ...hemicals known to the state of California to cause cancer birth defects and other reproductive harm WARNING CALIFORNIA PROPOSITION 65 WARNING Battery posts terminals and related accessories are known...

Page 3: ...3 1 Storage 3 1 Physical Location 3 2 Installation 3 2 Electrical Connections 3 2 Frame Ground Connection 3 3 Engine Oil 3 4 Recommended Engine Oil 3 4 Use of Electric Motor Loads 3 4 Optional Wheel K...

Page 4: ...ii Table of Contents MN2418...

Page 5: ...uipment at all times Keep non qualified personnel at a safe distance from this equipment Only qualified personnel familiar with the safe installation operation and maintenance of this device should at...

Page 6: ...should not be attempted Never start the engine unless you have first verified that the installation and operation of the generator are as described in this manual WARNING Be sure that you are complete...

Page 7: ...t whenever engine is running Electrical shock can cause serious or fatal injury Never operate electrical equipment while standing in water on wet ground or with wet hands feet or shoes or while barefo...

Page 8: ...extremities and cause serious or fatal injury WARNING Unauthorized modification of a generator set may make the unit unsafe for operation or may impair the operation of the unit Never start a generato...

Page 9: ...nk indoors or in an enclosed poorly ventilated area where gasoline fumes could reach an ignition source and cause an explosion Caution Statements Caution The brass connecting tab on some 120VAC duplex...

Page 10: ...1 6 Product Safety Information MN2418...

Page 11: ...nstallation shipment or otherwise Problems with Baldor products can be due to improper maintenance faulty installation non Baldor additions or modifications or other problems not due to defects in Bal...

Page 12: ...2 2 General Information MN2418...

Page 13: ...ad the following guidelines prior to storing the unit 1 Remove all fuel from the engine s fuel tank 2 Start the generator set and allow it to run out of fuel 3 Close all the fuel valves Note An altern...

Page 14: ...se severe illness or death Never breath exhaust fumes produced by a running engine Only run the engine outdoors where ventilation is plentiful Exhaust gases contain carbon monoxide a colorless odorles...

Page 15: ...he generator to the load The gauge of the wire will depend on the distance to the load the permissible voltage drop at the load and the current required by the load If you are not sure of the gauge wi...

Page 16: ...ch more current amperes to start them than to keep them running Some motors particularly split phase motors are very difficult to start and require 5 to 7 times more current to start them Repulsion in...

Page 17: ...censed electrician has installed an approved transfer switch Multiple receptacles may be used at the same time provided the total electrical load does not exceed the generators rated output 120Volts P...

Page 18: ...rope to snap back into the recoil housing Note If the engine does not start after several attempts smell for fuel near the air cleaner If there is a significant gasoline smell coming from the air clea...

Page 19: ...er s manual 4 Replace the spark plug s as is recommended by the engine manufacturer 5 Clean the cooling fins on the engine to keep the engine s heat dissipation potential at it s maximum 6 Inspect and...

Page 20: ...orque of terminals Replace worn bearing Low output voltage Low engine speed Excessive load High resistance connections connections will be warm or hot Shorted field Low power factor Check that the Aut...

Page 21: ...replacing a receptacle inspect the brass tab that normally links both receptacles If it is removed be sure to remove the brass tab from the replacement receptacle before it is installed Failure to re...

Page 22: ...A 2 PowerchiefR Series MN2418 Figure A 2 PG6000 Wiring Diagram...

Page 23: ...arranty on EVAP emission related parts is as follows Any warranted part that is not scheduled for replacement as required maintenance in the written instructions supplied is warranted for the warranty...

Page 24: ...this product contains chemicals known to the state of California to cause cancer birth defects and other reproductive harm WARNING CALIFORNIA PROPOSITION 65 WARNING Battery posts terminals and related...

Page 25: ...Baldor District Offices...

Page 26: ...he state of California to cause cancer birth defects and other reproductive harm WARNING CALIFORNIA PROPOSITION 65 WARNING Battery posts terminals and related accessories are known to the state of Cal...

Reviews: