Section 4
Operation
Operation 4-1
MN2411
Operator Control Panel
The Operator Control Panel is shown in Figure 4-1.
Figure 4-1 Operator Control Panel
AUTO
POWER
SAVE
PILOT
LAMP
OVER
LOAD
ON
OFF
STOP
RUN
CHOKE
BATTERY CHARGE ONLY
ON
OFF
+
−
−
+
ENGINE SWITCH
DC12V − 8.3A
~ AC OUTPUT
AC
AC Circuit Breaker
DC Circuit Breaker
Pilot Lamp
Lamp (Green) is ON when generator is running properly.
Overload Lamp *
Lamp (Red) is ON when generator is running and an overload condition exists.
If Overload Lamp is ON, Stop the generator and Start the generator again to resume
operation.
Oil Level Lamp
Lamp is on when engine oil level is less than a predetermined level. When the lamp
turns ON, the engine will stop automatically. If Oil Lamp is ON, replenish the engine oil
level and restart the engine.
Auto Power Save *
OFF. Generator runs at full speed and produces full power. Use OFF for DC power.
(switch)
ON. Generator idles during no load condition and automatically resumes full
speed when a load demand is present.
*
Available only on PC1700RI.