Thermostats
The thermostat is a pilot circuit device used in a protective relay circuit. Thermostat ratings are given in Table 2−3.
Table 2-3 Thermostat Ratings
Maximum Current Ratings for Thermostats (Normally Open or Closed Contacts)
Voltage
125VAC
250VAC
24VDC
Continuous Current All Voltages
Amperage
12A
8A
2A
2A
Blower Ventilation System
Before loading a force-ventilated motor, be sure that the blowers, cooling fans, or central air supply systems
are operating properly to supply cooling air to the motor. Air filters should also be in place. If you energize the
main fields with the motor at standstill, the blowers or external cooling systems must be left on. This will prevent
excessive heat buildup that will decrease the life of the insulation.
When using field economy circuits to reduce the voltage to the main fields during standstill, blowers do not need
to be left on.
Blower motors should be checked for correct rotation. Don’t rely on feeling airflow from the drive end of the
motor. Look at the outline drawing or rotation arrow shown on the blower housing. Refer to Figure 2-2.
Figure 2-2 View from Air Inlet (Motor is on Opposite Side)
Table 2-4 Electrical Data - Forced Ventilation Blower Units
Size
Motor Frame
HP
RPM
Volts
Phase
Hz
Amps
LM2
180
1/40
3000
230
1
60
0.4
LM3
180
1/8
3450
115/230
1
50/60
2.6/1.3
LM3
210-250
1/8
3450
208-230/460
3
50/60
0.66-0.60/0.30
LM4
280
1/3
3450
208-230/460
3
50/60
1.5-1.4/0.7
LM6
320-400
1
3450
208-230/460
3
50/60
3.1-3.0/1.5
LM8
504-506
3/4
1750
208-230/460
3
50/60
3.4-3.2/1.6
LM9
508-5012
3
3450
208-230/460
3
50/60
8.2-7.6/3.8
Note: Motor mounted blower units. Mount on commutator end (opposite drive end of motor. We supply blowers that are powered by totally enclosed motors (standard).
Blowers have a cast aluminum fan housing with washable, wire mesh filters.
A
B
K
H
G
J
C
F
E
D
A
H
B
J
C
K
D
F
E
A
A
B
B
C
C
+5V
COMMON
Electrically
Isolated
Encoder
Color Codes for Optional
Baldor Encoder Cable
Standard Receptacle MS3112W12−10P
Standard Plug
MS3116J12−10S
Air Inlet
Housing
Impeller
Blades
Airflow