Balcrank 3330-102 Operation, Installation, Maintenance And Repair Manual Download Page 3

3

ParTS lIST

TrOUbleShOOTInG GUIDe

revision log:

Rev. A - Service Bulletin Release

1

TrOUble

CaUSe

reMeDy

No fluid passing through the meter

A. Blocked strainer

B. Dirt particles jamming the rotors

C. Damaged plunger seal

A. Clean or replace strainer

B. Dismantle meter assembly and clean

C. Replace grip

The meter is not registering fluid ouput Damaged mechanical meter

Replace mechanical meter

Constant oil leak from the tip

Damaged plunger seal

Replace lance

Intermittent drip from the tip

A. Dirt in the tip

B. Tip not closed

A. Remove the tip and blow out and dirt 

particles, replace if necessary

B. Tip must be manually closed

Low flow rate

Blocked strainer

Replace strainer

Oil leaking from the swivel inlet

A. Connection not properly sealing

B. Damaged o-ring or swivel

A. Re-apply thread sealant and tighten

B. Replace grip

ITEM

PART #

DESCRIPTION

1

829482

Handle w/ swivel

2

806895

O-ring, Buna 70A, -112

3

832169

Adapter, 1/2” NPT 

x 3/8” NPSM

4

832272

Mechanical Meter

5

832190

Rigid Lance

6

831789

Flex 90 Lance

7

832199

Flex Lance

OPeraTIOn

Connect the control handle to the lubricant supply line 

1. 

(1/2” NPT male thread required).

Open the manual tip.

2. 

Press the reset button to zero out the reset total.

3. 

To dispense, squeeze control handle trigger. When the 

4. 

desired amount of product has been dispensed (read 

in quarts) release trigger to stop delivery. 

Close the manual tip & wipe it clean with a rag.

5. 

Press the reset button to zero out the reset total.

6. 

4

3

6

5

7

2

Reviews: