3
ParTS lIST
TrOUbleShOOTInG GUIDe
revision log:
Rev. A - Service Bulletin Release
1
TrOUble
CaUSe
reMeDy
No fluid passing through the meter
A. Blocked strainer
B. Dirt particles jamming the rotors
C. Damaged plunger seal
A. Clean or replace strainer
B. Dismantle meter assembly and clean
C. Replace grip
The meter is not registering fluid ouput Damaged mechanical meter
Replace mechanical meter
Constant oil leak from the tip
Damaged plunger seal
Replace lance
Intermittent drip from the tip
A. Dirt in the tip
B. Tip not closed
A. Remove the tip and blow out and dirt
particles, replace if necessary
B. Tip must be manually closed
Low flow rate
Blocked strainer
Replace strainer
Oil leaking from the swivel inlet
A. Connection not properly sealing
B. Damaged o-ring or swivel
A. Re-apply thread sealant and tighten
B. Replace grip
ITEM
PART #
DESCRIPTION
1
829482
Handle w/ swivel
2
806895
O-ring, Buna 70A, -112
3
832169
Adapter, 1/2” NPT
x 3/8” NPSM
4
832272
Mechanical Meter
5
832190
Rigid Lance
6
831789
Flex 90 Lance
7
832199
Flex Lance
OPeraTIOn
Connect the control handle to the lubricant supply line
1.
(1/2” NPT male thread required).
Open the manual tip.
2.
Press the reset button to zero out the reset total.
3.
To dispense, squeeze control handle trigger. When the
4.
desired amount of product has been dispensed (read
in quarts) release trigger to stop delivery.
Close the manual tip & wipe it clean with a rag.
5.
Press the reset button to zero out the reset total.
6.
4
3
6
5
7
2