background image

Rev20200511 

o.  Reconnect the unit to the spa controller and reinstall the spa controller’s cover. 
p.  Turn ON the power to the spa. 
q.  Once power is activated you can check the LEDs to see if the unit is functioning. A solid green light indicates the unit 

is being provided power and should always be on. A solid blue light indicates that UV-C lamp is activated. 

r. 

Warning:

 The UV-C lamp used in this unit contains mercury. Properly dispose the old UV-C lamp in accordance with 

disposal laws. See 

www.lamprecycle.org

.  

Summary of Contents for Wavezone3NE

Page 1: ...Rev20200511 INSTALLATION INSTRUCTIONS AND MAINTENANCE MANUAL FOR BALBOA WAVEZO3NE SANITITION SYSTEM BALBOA WATER GROUP www balboawater com 3030 Airway Avenue Suite B Costa Mesa CA 92626 USA ...

Page 2: ...ilizes the powerful oxidation ability of hydroxyl radicals AOP is a chemical reaction process designed to remove organic and inorganic materials in the water through reaction with hydroxyl radicals AOP is based on production of hydroxyl radicals The more hydroxyl produced the better sanitation power The chemical formula of hydroxyl radical is OH Hydroxyl radical is highly reactive It is a stronges...

Page 3: ...bilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety 5 Children being supervised not to play with the appliance 6 This unit contains a UV C lamp 7 WARNING Do not operate the UV C lamp when it is removed from the unit enclosure Do not operate if this unit is obviously damaged 8 Un...

Page 4: ...e 4x 8x1 screws to bolt the unit to the spa floor or spa wooden frame c Clearance required i 9 minimum from the front of cover ii 9 minimum from the top of cover VI Plumbing A Use 3 4 clear flexible hoses 3 4 hose clamps for both inlet and outlet connections B Water inlet to be on the bottom of the unit C This unit can be plumbed with one of the bellow options a Option 1 b Option 2 ...

Page 5: ...th the spa common bonding grid with a 8 minimum solid copper wire IX Exploded drawing KEY DESCRIPTION 1 ENCLOSURE TOP COVER 1a ENCLOSURE FRONT COVER 2 STRAIN RELIEF 3 AIR FILTER 4 BRACKET FOR DUAL OZONE CELL 5 OZONE CELL 6 OZONE HOSE CLAMP 7 QUARTZ SEAL GASKET 8 BOOT COVER 9 UPPER CUSHION 10 UV LAMP 10a LAMP CONNECTOR 11 LOWER CUSHION 12 COMPRESSION NUT 13 PLASTIC WASHER 14 COMPRESSION WASHER 15 Q...

Page 6: ... water is visible STOP and tighten the compression nut another quarter of a turn with a pair of Channel Lock pliers to make sure a complete seal Make sure there is no water leaking anywhere before proceeding to the next step t Turn the breaker back on Turn on the pump to circulate the water through the unit Wait for 5 minutes and assure no water is dripping If water is visible STOP fix the leak by...

Page 7: ...d you can check the LEDs to see if the unit is functioning A solid green light indicates the unit is being provided power and should always be on A solid blue light indicates that UV C lamp is activated r Warning The UV C lamp used in this unit contains mercury Properly dispose the old UV C lamp in accordance with disposal laws See www lamprecycle org ...

Reviews: