Adjusting Filtration
FILT1: Main Filtration
Filter cycles are set using a start time and a duration. Start time is indicated by
an “A” or “P” in the bottom right corner of the display. Duration has no “A” or
“P” indication. Each setting can be adjusted in 15-minute increments. The panel
calculates the end time and displays it automatically.
FILT2, Filter Cycle 2: Optional Filtration
Filter Cycle 2 is OFF by default.
It is possible to overlap Filter Cycle 1 and Filter Cycle 2, which will shorten overall
filtration by the overlap amount.
Purge Cycles
In order to maintain sanitary conditions, secondary Pumps and/or a Blower
t
will purge water from their respective plumbing by running briefly at the
beginning of each filter cycle.
If Filter Cycle 1 is set for 24 hours, enabling Filter Cycle 2 will initiate a purge
t
when Filter Cycle 2 is programmed to begin.
The following pages describe how to set up filtration times.