Balboa ML700 User Manual Download Page 6

Light  

Some systems are equipped with both a spa light and a 
fiber optic light; however, only one can be accessed by this 
panel. (Larger panels may be purchased so that both the 
spa light and fiber optic light can be utilized.) Depending 
upon how your spa is equipped and configured, the 
“Light” button will operate in one of three ways:

1) Press the “Light” button to turn the spa light on and 
off, and to shift between dim and bright settings if your 
light is dimmable. On dim, the LCD will show center 
circle plus one quarter of the light beams. Half of the 
light beams will show on medium brightness, and all of 
the light beams will show on bright.

2) If a fiber-optic light with wheel is installed, press the 
“Light” button once to start the light and wheel, press 
it again to stop the wheel, and then again to turn the 
light off. The fiber icon stands still when the fiber optic 
light is on by itself, and rotates when the color wheel is 
also on.

3) If a fiber-optic light without a separate wheel stop is 
installed, press the “Light” button to turn it on and off.

Again, both a spa light and a fiber optic light may be 
used simultaneously on the EL8000 and EL5000 systems 
with a different panel.

If any light is left on, it will automatically turn off after a 
factory programmed time period.

Freeze Protection

If the temperature sensors within the heater detect a low 
enough temperature, then the pump(s) and the blower 
automatically activate to provide freeze protection. The 
pump(s) and blower will run either continuously or 
periodically depending on conditions.

In colder climates, an optional additional freeze sensor 
may be added to protect against freeze conditions that 
may not be sensed by the standard sensors. Auxiliary 
freeze sensor protection acts similarly except with the 
temperature thresholds determined by the switch. See 
your dealer for details.

Locking the Panel

Press “Time” “Jets 1” then “Warm” within 3 seconds. 
When locked, the PL “

PL

” light will light. All buttons 

are frozen except the “Time” button. To unlock the 
panel, press “Time” “Jets 1” then “Cool.”

Locking the Set Temperature

Press “Warm” or “Cool” then “Time,” “Jets 1,” and 
“Warm” within 3 seconds to activate the lock. The 
TL “

TL

” light will light when the set temperature 

is locked.

On some systems, locking the set temperature also locks 
out Mode changes.

To unlock the set temperature, press “Warm” or “Cool” 
then “Time,” “Jets 1” and “Cool.”

Clean-up Cycle

(optional)

When a pump or blower is turned on by a button 
press, a clean-up cycle begins 30 minutes after the 
pump or blower is turned off or times out. The pump 
and the ozone generator will run for one to four hours, 
depending on the system (on some systems, you can 
change this setting; see User Preferences section.)

Circ Pump

(optional)

If your system is equipped with a circ pump, it may be 
configured to work in one of three different ways:

1) The circ pump operates continuously (24 hours) with 
the exception of turning off for 30 minutes at a time 
when the water temperature reaches 3°F (1.5°C) above 
the set temperature (most likely to happen in very 
hot climates).

2) The circ pump stays on continuously, regardless of 
water temperature.

3) The circ pump will come on when the system is 
checking temperature (polling), during filter cycles, 
during freeze conditions, or when another pump is on.

Ozone

(optional)

On most systems, the ozone generator (if installed) runs 
during filter cycles (except when pump 1 is operating at 
high speed on a non-circ system) and during clean-up 
cycles. On some systems, the ozone generator operates 
whenever the pump runs.

If your system is configured with the optional ozone 
suppress feature, the ozone generator will turn off for 
1 hour any time a function button (Jets 1, Jets 2, Blower, 
etc.) is pressed.

Page 4

Note: 

If your spa has additional functions not listed 

here, please refer to the section 

Optional Auxiliary 

Panels 

as listed in the Table of Contents.

Summary of Contents for ML700

Page 1: ...t Jets 1 F2 TL F1 PL 900854 ML700 User Guide EL GL Series Mach 3 Note regarding EL and GL systems Mach 3 EL and GL systems function identically but conform to different International requirements This user guide will refer to EL systems for the sake of simplicity but the information given applies to both EL and GL products ...

Page 2: ......

Page 3: ...in sequence they may not register Table of Contents EL GL SERIES Mach 3 CONTROL 1 Initial Start up 1 Icon Legend 1 Time 2 Setting the Time 2 Temp Set 2 Warm Cool 2 Mode Prog 2 Standby Mode 2 Jets 1 2 Jets 2 3 Blower 3 Invert 3 Preset Filter Cycles 3 Optional Filter Cycle Programming 3 Light 4 Freeze Protection 4 Locking the Panel 4 Locking the Set Temperature 4 Clean up Cycle 4 Circ Pump 4 Ozone 4...

Page 4: ...tton resets the spa On some systems the Jets 1 button will control the pump in Standby Mode Drain Mode In this case press any other button to exit System will revert to previous mode after 1 hour Jets 1 Press the Jets 1 button once to turn pump 1 on or off and to shift between low and high speeds if equipped If left running the pump will turn off after a timeout period The pump 1 low speed timeout...

Page 5: ...ilter cycle night begins 12 hours later Filter duration is programmable for 1 12 hours The default filter duration can vary from system to system To program press Warm or Cool then Jets 1 Press Warm or Cool to select the filter duration Press Jets 1 to select the number of filter cycles The display will show both day and night cycles day cycle only or night cycle only Press Warm or Cool to adjust ...

Page 6: ... dealer for details Locking the Panel Press Time Jets 1 then Warm within 3 seconds When locked the PL PL light will light All buttons are frozen except the Time button To unlock the panel press Time Jets 1 then Cool Locking the Set Temperature Press Warm or Cool then Time Jets 1 and Warm within 3 seconds to activate the lock The TL TL light will light when the set temperature is locked On some sys...

Page 7: ...24 hour military format 00 00 is midnight 23 00 is one hour before midnight When set to time is displayed in 12 hour am pm format 12 00 is midnight 11 00 pm is one hour before midnight Clean up Cycle Duration some systems only When set to Clean up Cycles are disabled When set to through the number indicates how many hours each Clean up Cycle will run Dolphin II Address When set to no addressing is...

Page 8: ...nce the heater has cooled reset by pushing any button If spa does not reset shut off the power to the spa and call your dealer or service organization DO NOT ENTER THE WATER Remove the spa cover and allow water to cool At 107 F approximately 41 7 C the spa should automatically reset If spa does not reset shut off the power to the spa and call your dealer or service organization No action required ...

Page 9: ...nt spa temperature either switch to Standard mode or turn Jets 1 on for at least 1 minute Press any button except Jets 1 to leave Standby Mode and return to normal operation Add pH increaser according to manufacturer s instructions Add pH reducer according to manufacturer s instructions Add sanitizer according to manufacturer s instructions Remove spa cover and allow sanitizer to dissipate Press J...

Page 10: ...st reset the GFCI and the spa will operate normally from that point You can verify a successful test by navigating to the item as described above pressing Jets 1 and then pressing the Warm button until you see The code signifies GFCI Status Passed The system will exit this menu in 30 seconds if no buttons are pressed Periodic Reminder Messages Press the Mode button to reset a displayed reminder Me...

Page 11: ...n to raise and lower the TV Lift device There is no timeout for this feature Fiber optional on some systems If a fiber optic light with wheel is installed press the Fiber button once to start the light and wheel press it again to stop the wheel and then again to turn the light off The fiber icon stands still when the fiber optic light is on by itself and rotates when the color wheel is also on Bot...

Page 12: ...he spa Read the instruction manual Adequate drainage must be provided if the equipment is to be installed in a pit For use only within an enclosure rated CSA Enclosure 3 Connect only to a circuit protected by a Class A ground fault circuit interrupter To ensure continued protection against shock hazard use only identical replacement parts when servicing Install a suitably rated suction guard to ma...

Reviews: