Temp Set 

(80°F - 104°F / 26.0°C - 40.0°C)

The last measured temperature is constantly displayed 
on the LCD. Your spa’s set temperature range may 
vary from range shown above depending on your 
manufacturer’s settings.

Note that the last measured spa temperature displayed is 

current only when the pump has been running for at least 

1 minute.

Warm/Cool  

  

Press the “Warm” or “Cool” button once to display the 
set temperature. Each time either button is pressed again, 
the set temperature will increase or decrease depending 
on which button is pressed. After three seconds, 
the LCD will automatically display the last measured 
spa temperature.

Mode/Prog  

This button is used to switch between Standard, 
Economy, and Sleep modes. Press “Mode/Prog” to enter 
mode programming, press “Cool” to cycle through to 
desired mode (LCD flashes until confirmed), then press 
“Mode/Prog” to confirm selection.

Standard mode 

maintains the desired temperature. Note 

that the last measured spa temperature displayed is 
current only when the pump has been running for at 
least 1 minute. The “

” icon will display until the 

mode is changed.

Economy mode

 heats the spa to set temperature only 

during filter cycles. The “

” icon will display 

until mode is changed.

Pressing “Jets 1” while in Economy mode puts the 
spa in 

Standard-In-Economy mode, 

which operates 

the same as Standard Mode, then reverts to Economy 
Mode automatically after 1 hour. Both the “

and “

” icons display in this mode. During this 

time, a press of the “Mode/Prog” button will revert to 
Economy Mode immediately.

Sleep mode

 heats the spa to within 20°F (11°C) of the set 

temperature only during filter cycles. The “

” icon 

will display until mode is changed.

Standby Mode

Pressing “Warm” or “Cool” then “Jets 2” will turn off all 
spa functions temporarily. This is helpful when changing 
a filter. Pressing any button resets the spa. On some 
systems the “Jets 1” button will control the pump in 
Standby Mode (“Drain Mode”). In this case, press any 
other button to exit. System will revert to previous mode  
after 1 hour.

Jets 1  

Press the “Jets 1” button once to turn pump 1 on or off, 
and to shift between low and high speeds if equipped. 
If left running, the pump will turn off after a timeout 
period. The pump 1 low speed timeout on some systems 
may be as long as 4 hours.

On non-circ systems, the low speed of pump 1 runs 
when the blower or any other pump is on. It may also 
activate for at least 1 minute every 30 minutes to detect 
the spa temperature (polling) and then to heat to the 
set temperature if needed, depending upon mode. 
When the low speed turns on automatically, it cannot 
be deactivated from the panel; however, the high speed 
may be started.

Time  

When time hasn’t been programmed, the “

” icon 

flashes. To set the time, press “Time” then “Mode/Prog.” 
Use the “Warm” and “Cool” buttons to adjust time. See 
previous page for more detailed instructions. 

(Time 

settings on EL1000 and some EL2000 systems are not 
preserved in the event of power loss; time will have to be 
reprogrammed upon each power up.)

If your spa has an optional pH/ORP sensor (not 
available on EL1000 and some EL2000 systems), pressing 
“Time” twice will display the current pH level; pressing 
it three times will display the current ORP.

Page 2

Setting the Time

Once the spa has been properly connected the first time (every power 

up on the EL1000 and some EL2000 systems), notice the “

” icon 

appearing on the screen.

Press

Then

Select 

the hour by pressing

Press

to exit the time setting procedure and enter 
the optional filter cycle programming. (Exits 
programming on EL1000 and some EL2000 systems.)

Time

Time

Press

to exit programming.

Press

to enter.

Select 

minutes by pressing

Mode/Prog

Mode/Prog

Time

Time

Mode/Prog

Mode/Prog

Mode/Prog

Mode/Prog

Or

(Each press changes the 
time by 1 minute)

Warm

Warm

Cool

Cool

Or

(Each press changes the 
time by 1 minute)

Warm

Warm

Cool

Cool

Summary of Contents for ML700

Page 1: ...t Jets 1 F2 TL F1 PL 900854 ML700 User Guide EL GL Series Mach 3 Note regarding EL and GL systems Mach 3 EL and GL systems function identically but conform to different International requirements This user guide will refer to EL systems for the sake of simplicity but the information given applies to both EL and GL products ...

Page 2: ......

Page 3: ...in sequence they may not register Table of Contents EL GL SERIES Mach 3 CONTROL 1 Initial Start up 1 Icon Legend 1 Time 2 Setting the Time 2 Temp Set 2 Warm Cool 2 Mode Prog 2 Standby Mode 2 Jets 1 2 Jets 2 3 Blower 3 Invert 3 Preset Filter Cycles 3 Optional Filter Cycle Programming 3 Light 4 Freeze Protection 4 Locking the Panel 4 Locking the Set Temperature 4 Clean up Cycle 4 Circ Pump 4 Ozone 4...

Page 4: ...tton resets the spa On some systems the Jets 1 button will control the pump in Standby Mode Drain Mode In this case press any other button to exit System will revert to previous mode after 1 hour Jets 1 Press the Jets 1 button once to turn pump 1 on or off and to shift between low and high speeds if equipped If left running the pump will turn off after a timeout period The pump 1 low speed timeout...

Page 5: ...ilter cycle night begins 12 hours later Filter duration is programmable for 1 12 hours The default filter duration can vary from system to system To program press Warm or Cool then Jets 1 Press Warm or Cool to select the filter duration Press Jets 1 to select the number of filter cycles The display will show both day and night cycles day cycle only or night cycle only Press Warm or Cool to adjust ...

Page 6: ... dealer for details Locking the Panel Press Time Jets 1 then Warm within 3 seconds When locked the PL PL light will light All buttons are frozen except the Time button To unlock the panel press Time Jets 1 then Cool Locking the Set Temperature Press Warm or Cool then Time Jets 1 and Warm within 3 seconds to activate the lock The TL TL light will light when the set temperature is locked On some sys...

Page 7: ...24 hour military format 00 00 is midnight 23 00 is one hour before midnight When set to time is displayed in 12 hour am pm format 12 00 is midnight 11 00 pm is one hour before midnight Clean up Cycle Duration some systems only When set to Clean up Cycles are disabled When set to through the number indicates how many hours each Clean up Cycle will run Dolphin II Address When set to no addressing is...

Page 8: ...nce the heater has cooled reset by pushing any button If spa does not reset shut off the power to the spa and call your dealer or service organization DO NOT ENTER THE WATER Remove the spa cover and allow water to cool At 107 F approximately 41 7 C the spa should automatically reset If spa does not reset shut off the power to the spa and call your dealer or service organization No action required ...

Page 9: ...nt spa temperature either switch to Standard mode or turn Jets 1 on for at least 1 minute Press any button except Jets 1 to leave Standby Mode and return to normal operation Add pH increaser according to manufacturer s instructions Add pH reducer according to manufacturer s instructions Add sanitizer according to manufacturer s instructions Remove spa cover and allow sanitizer to dissipate Press J...

Page 10: ...st reset the GFCI and the spa will operate normally from that point You can verify a successful test by navigating to the item as described above pressing Jets 1 and then pressing the Warm button until you see The code signifies GFCI Status Passed The system will exit this menu in 30 seconds if no buttons are pressed Periodic Reminder Messages Press the Mode button to reset a displayed reminder Me...

Page 11: ...n to raise and lower the TV Lift device There is no timeout for this feature Fiber optional on some systems If a fiber optic light with wheel is installed press the Fiber button once to start the light and wheel press it again to stop the wheel and then again to turn the light off The fiber icon stands still when the fiber optic light is on by itself and rotates when the color wheel is also on Bot...

Page 12: ...he spa Read the instruction manual Adequate drainage must be provided if the equipment is to be installed in a pit For use only within an enclosure rated CSA Enclosure 3 Connect only to a circuit protected by a Class A ground fault circuit interrupter To ensure continued protection against shock hazard use only identical replacement parts when servicing Install a suitably rated suction guard to ma...