background image

Summary of Contents for EL Series

Page 1: ... Light Temp Jets Aux Light Temp Jets Note regarding EL and GL systems Mach 3 EL and GL systems function identically but conform to different International requirements This user guide will refer to EL systems for the sake of simplicity but the information given applies to both EL and GL products 900854 ...

Page 2: ......

Page 3: ...e shutting off automatically Certain conditions filters or freeze can cause a function to operate longer while faults can cause a function to operate for a shorter length of time The system keeps track of timeouts regardless of other conditions occurring In multi button sequences if buttons are pressed too quickly in sequence they may not register Table of Contents EL GL SERIES Mach 3 CONTROL 1 In...

Page 4: ... Mode Pressing Temp followed by Aux or Jets 2 or Blower will turn off all spa functions temporarily This is helpful when changing a filter Pressing any button exits Standby mode On some systems the Jets button will control the pump in Standby Mode Drain Mode In this case press any other button to exit System will revert to previous mode after 1 hour Jets Press the Jets button once to turn pump 1 o...

Page 5: ... the temperature thresholds determined by the switch See your dealer for details Locking Features If this panel is used as the main panel locking features will not be available If this panel is used as a remote or additional panel it will lock when the main panel is locked To unlock this panel unlock the main panel In the same way the set temperature can be locked and unlocked by a main panel When...

Page 6: ... factory default When set to through the number is the address see your Dolphin II manual for details Editing User Preferences View the setting The left two characters before the decimal point tell you what setting you re viewing or editing the right most character after the decimal point tells you the value of that setting for example for Yes or for No If the value is flashing you re editing it I...

Page 7: ... reset the GFCI and the spa will operate normally from that point You can verify a successful test by navigating to the item as described above pressing Jets and then pressing the Temp button until you see The code signifies GFCI Status Passed The system will exit this menu in 30 seconds if no buttons are pressed Periodic Reminder Messages Press the Temp button to reset a displayed reminder Messag...

Page 8: ...l Once the heater has cooled reset by pushing any button If spa does not reset shut off the power to the spa and call your dealer or service organization DO NOT ENTER THE WATER Remove the spa cover and allow water to cool At 107 F approximately 41 7 C the spa should automatically reset If spa does not reset shut off the power to the spa and call your dealer or service organization No action requir...

Page 9: ... solid on the display when the temperature is not current will alternate with the temperature when the temperature is current Operates the same as Standard mode then reverts to Economy mode after 1 hour Press Temp followed by Light to switch directly to Economy mode will appear solid on the display when the temperature is not current will alternate with the temperature when the temperature is curr...

Page 10: ...d operation med hi off or 3 speed operation lo med hi off If left on the blower will automatically turn off after a timeout period Fiber optional on some systems If a fiber optic light with wheel is installed press the Fiber button once to start the light and wheel press it again to stop the wheel and then again to turn the light off The fiber icon stands still when the fiber optic light is on by ...

Page 11: ...Connect only to a circuit protected by a Class A ground fault circuit interrupter To ensure continued protection against shock hazard use only identical replacement parts when servicing Install a suitably rated suction guard to match the maximum flow rate marked Warning Water temperature in excess of 38 C may be injurious to your health Disconnect the electrical power before servicing Attention To...

Page 12: ...Do not attempt service of this control system Contact your dealer or service organization for assistance Follow all owner s manual power connection instructions Installation must be performed by a licensed electrician and all grounding connections must be properly installed ...

Reviews: