IT Electrical System (No Neutral)
TN and TT Electrical Services (Line, Neutral, Ground), IT Power Requirements
Single Service [3 wires (line, line, ground)]
230VAC, 50Hz, 1þ, 16A/32A, (Circuit Breaker rating = 20A/40A max.)
Protective Earth Wire (Green/Yellow) must be connected to system ground
t
terminal as marked.
All equipment (pumps, blower, and heater) runs on service line L1 with L2
t
acting as the return - 230VAC.
Set the DIP switches according to the wiring diagram so that total system
t
current draw never exceeds the rated service input when using a particular
setup.
Three Service [4 wires (line, line, line, ground)]
230VAC, 50Hz, 1þ, 16A/32A, (Circuit Breaker rating = 20A/40A max.)
Protective Earth Wire (Green/Yellow) must be connected to system ground
t
terminal as marked.
All equipment (pumps, blower, and heater) runs on service line L1 with L2
t
acting as the return - 230VAC.
Set the DIP switches according to the wiring diagram so that total system
t
current draw never exceeds the rated service input when using a particular
setup.