Heater Installation Guide

4

3S Heater Installation 

©2019 Balboa Water Group.  Single Source Solution.  All rights reserved.
3030 Airway Avenue, Suite B | Costa Mesa, CA 92626  |  p 714.384.0384  |  www.balboawater.com 
Specifications subject to change without notice.

Step 4

Disconnect both M7 temperature sensors (A) from J16 

and J17 on the circuit board. The connectors have 

locking tabs (refer to page 1). Depress the locking tab 

before disconnecting the sensor from the circuit board.

Step 5

Remove the heater from the system pack. The heater 

is mounted to the system pack with two nuts on 

mounting posts (D). Loosen the nuts with an open 

ended 3/8” (9.5mm) wrench, and remove the heater.

Step 6

Install the new heater into the system pack, and 

tighten the two mounting nuts (D).

Step 7

Connect the M7 temperature sensors (A) to J16 and 

J17 on the circuit board. The locking tabs only align 

one way on the J16 and J17 connectors (refer to page 

1). Misalignment may cause damage.

Step 8

Connect the third temperature sensor switch (view “E” 

on page 2) to the circuit board at J29. The connector 

has alignment tabs that only align one way on the J29 

connector (view “E” on page 1). Misalignment may 

cause damage.  

Confirm that “HTR DISBL” or “HTR DSBL” is written near 
J29

 on the wiring diagram (view “H” and “ I “ on page 

1). If J29 isn’t thus labeled as Heater Disable, the 3S 

heater is incompatible with this system pack.
If something is already connected to J29,  

please contact our technical support at  

[email protected]

Step 9

If the agency prefix is BP501 or BP6, use an applicator 

stick to apply Nyogel 760G to the three metal contacts 

(G) on J46.

Step 10

If the agency prefix is BP501 or BP6, connect the heater 

connector (B) to J46 on the circuit board.
If the agency prefix is BP20 or BP21, connect the heater 

connector (B) to J44 on the circuit board.
You will hear a click when the connection is secure.

Step 11

Install the system pack lid and tighten the two 

mounting screws (F).

Step 12

Power On the system pack at the GFCI  

or circuit breaker.

If the agency prefix is BP20 or BP21, use an applicator 

stick to apply Nyogel 760G to the three metal contacts 

(G) on J44.
Cover all surfaces of the metal contacts. Nyogel 

provides corrosion protection.