EL/GL SERIES (Mach 3) CONTROL WITH ML400 PANEL

The ML400 panel can be used as a main panel 
with the EL2000 and EL1000 systems, but only as a 
remote/additional panel for the EL8000 and EL5000 
systems. This reference card lists all features that are 
available. Your spa may not respond as described in this 
document as specific operation varies by system and 
equipment used. If your spa is not fully equipped, the 
panel buttons on your spa control may not be laid out 
as shown. Functions not accessible by this panel may 
be accessible by a larger panel such as the ML700 or 
the ML900. One such example: This panel can be used 
with EL2000 systems equipped with two pumps plus a 
blower, but the blower cannot be controlled with this 
panel unless the system does not have a pump 2. In 
this case, the blower can be controlled with an optional 
auxiliary panel.

The pump responsible for heating and filtration (pump 1
low on non-circ systems, or the circ pump on circ 
systems) will be referred to simply as the pump.

Timeouts refer to a preset length of time that a 
function is programmed to operate before shutting off 
automatically. Certain conditions (filters or freeze) can 
cause a function to operate longer, while faults can 
cause a function to operate for a shorter length of time. 
The system keeps track of timeouts regardless of other 
conditions occurring.

In multi-button sequences, if buttons are pressed too 
quickly in sequence, they may not register.

Table of Contents

EL/GL SERIES (Mach 3) CONTROL   . . . . .   1
Initial Start-up  . . . . . . . . . . . . . . . . . . . . .   1
Temp Set   . . . . . . . . . . . . . . . . . . . . . . . .   2
Temp  . . . . . . . . . . . . . . . . . . . . . . . . . . .   2
Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . .   2
Standby Mode  . . . . . . . . . . . . . . . . . . . . .   2
Jets . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   2
Jets 2   . . . . . . . . . . . . . . . . . . . . . . . . . . .   2
Blower  . . . . . . . . . . . . . . . . . . . . . . . . . .   2
Circ Pump . . . . . . . . . . . . . . . . . . . . . . . .   2
Light . . . . . . . . . . . . . . . . . . . . . . . . . . . .   3
Ozone . . . . . . . . . . . . . . . . . . . . . . . . . . .   3
Clean-up Cycle  . . . . . . . . . . . . . . . . . . . .   3

Freeze Protection   . . . . . . . . . . . . . . . . . .   3
Locking Features  . . . . . . . . . . . . . . . . . . .   3
Preset Filter Cycles   . . . . . . . . . . . . . . . . .   3
Displaying Information About Your Spa  . .  3
User Preferences  . . . . . . . . . . . . . . . . . . .   4
Editing User Preferences  . . . . . . . . . . . . .   4
Periodic Reminder Messages  . . . . . . . . . .   5
GFCI Protection . . . . . . . . . . . . . . . . . . . .   5
GFCI Trip Test Procedure   . . . . . . . . . . . .   5
Diagnostic Messages  . . . . . . . . . . . . . .   6-7
Optional Auxiliary Panels   . . . . . . . . . . . .   8
Basic Installation Guidelines   . . . . . . . . . .   9
CSA Compliance  . . . . . . . . . . . . . . . . . . .  9

Page 1

Initial Start-up

When your spa is first actuated, it will go into Priming 
mode (after displaying some configuration information). 

Please see the M-7 Installation Instruction Manual for 
complete instructions on Power-up and Pump Priming.

The Priming mode will last for up to 4 minutes and 

then the spa will begin to heat and maintain the water 
temperature in the Standard mode. You can exit Priming 
mode early by pressing “Temp”.

Summary of Contents for ML400

Page 1: ...ets Aux Temp Light Note regarding EL and GL systems Mach 3 EL and GL systems function identically but conform to different International requirements This user guide will refer to EL systems for the s...

Page 2: ......

Page 3: ...re shutting off automatically Certain conditions filters or freeze can cause a function to operate longer while faults can cause a function to operate for a shorter length of time The system keeps tra...

Page 4: ...ing filter cycles will appear on the display until mode is changed Standby Mode Pressing Temp followed by Aux or Jets 2 or Blower will turn off all spa functions temporarily This is helpful when chang...

Page 5: ...ensor may be added to protect against freeze conditions that may not be sensed by the standard sensors Auxiliary freeze sensor protection acts similarly except with the temperature thresholds determin...

Page 6: ...hin II which is set for no address which is the Dolphin II factory default When set to through the number is the address see your Dolphin II manual for details Editing User Preferences View the settin...

Page 7: ...reset the GFCI and the spa will operate normally from that point You can verify a successful test by navigating to the item as described above pressing Jets and then pressing the Temp button until you...

Page 8: ...nce the heater has cooled reset by pushing any button If spa does not reset shut off the power to the spa and call your dealer or service organization DO NOT ENTER THE WATER Remove the spa cover and a...

Page 9: ...lid on the display when the temperature is not current will alternate with the temperature when the temperature is current Operates the same as Standard mode then reverts to Economy mode after 1 hour...

Page 10: ...TV Lift device There is no timeout for this feature Blower 1 speed operation on off 2 speed operation med hi off or 3 speed operation lo med hi off If left on the blower will automatically turn off a...

Page 11: ...nnect only to a circuit protected by a Class A ground fault circuit interrupter To ensure continued protection against shock hazard use only identical replacement parts when servicing Install a suitab...

Page 12: ...o not attempt service of this control system Contact your dealer or service organization for assistance Follow all owner s manual power connection instructions Installation must be performed by a lice...