Connecting the VK-P6 to Your System

 

 

 

Cartridge Input

 

 

 

The back panel of the VK-P6 phono stage is equipped with one set of RCA 

cartridge input connectors. 

 

 

Output Connection

 

 

The VK-P6 is equipped with XLR output connectors.  Any high quality set of 

balanced interconnects can be used to connect the VK-P6 to your balanced 

preamplifier.   

 

Single-ended preamplifiers can be connected to the VK-P6 output through 

the use of XLR-to-RCA adapters, available from BAT. 

 

 

 

Description of Controls

 

 

Power Switch

 

 

The power switch toggles between two positions: OFF and ON.  Turning the 

unit OFF  (even for a short period of time) will reset the soft start and mute 

circuits.  The VK-P6 will then require about 45 seconds to return back to 

normal operation. 

 

When you turn the unit ON, the VK-P6 will automatically go through a gentle 

power-on sequence.  At the end of this sequence the unit will automatically 

unmute.  However, since the source volume may be unknown at this time, it is 

advisable to turn the volume control on your preamplifier fully 

counterclockwise and place the mute switch in "Mute" position before 

turning the VK-P6 ON. 

 

 

Output Muting 

 

Summary of Contents for VK-P6

Page 1: ..._______________ Address _______________________________________ _______________________________________ Date of Purchase _______________________________________ Purchased From Dealer Name ____________...

Page 2: ...r with a copy of your sales receipt to Balanced Audio Technology at the address below within thirty days of purchase Failure to do so will result in the product being warrantied for one year from the...

Page 3: ...VK P6 Balanced Phono Stage Owner s Manual 1300 First State Blvd Wilmington DE 19804 Tel 302 999 8855 Fax 302 999 8818...

Page 4: ...was preset at the factory to the following configuration Gain High Input Resistive Loading 47k Input Capacitive Loading None Please refer to the chapter on configuration switch setting for information...

Page 5: ...or fire DO NOT operate with the cover removed DO NOT expose to rain or moisture DO NOT defeat the ground power plug DO NOT replace fuse with anything other than the same type and rating as supplied by...

Page 6: ...lation Mount the unit on a hard surface with proper ventilation underneath Do not stack the VK P6 phono stage on top of other units nor vice versa General Description of VK P6 Phono Preamplifier The V...

Page 7: ...iption of Controls Power Switch The power switch toggles between two positions OFF and ON Turning the unit OFF even for a short period of time will reset the soft start and mute circuits The VK P6 wil...

Page 8: ...in VK P6 Hazardous voltages are present on the unit s printed circuit board DO NOT operate the VK P6 with its top cover removed This section describes the setting of internal configuration switches th...

Page 9: ...d This is accomplished by using the two DIP switches S101 and S201 that allow multiple choices for resistive and capacitive cartridge loading Four positions are reserved for the choice of resistance a...

Page 10: ...ned Any possible parallel combination of these values is also allowable Gain Switch By moving the switch S2 from High to Low position the amplifier s gain is reduced by about 6dB While the High gain p...

Page 11: ...with the same type and rating parts Servicing The Balanced Audio Technology VK P6 should require no service other than changing tubes to maintain its high performance The vacuum tubes used in the VK P...

Page 12: ...eferenced to 1mV Low position 71dB High Position 73dB Cartridge Loading Resistance Selectable from 100 to 47k Capacitance Selectable from 100pF to 1000pF Inputs RCA Connectors Outputs XLR Balanced XLR...

Page 13: ...y anyone other than Balanced Audio Technology or its specifically authorized agents 5 Remedy If this product contains a materials manufacturing or workmanship defect that cannot be repaired at the dea...