4
C. GAS CONNECTIONS
1. INSTALLATION INSTRUCTIONS
A.
SAFETYPRECAUTIONS
RETAIN THIS MANUAL FOR FUTURE REFERENCE.
B. UNPACKINGINSTRUCTIONS:
FORYOUR SAFETY, THE FOLLOWINGSAFETYPRECAUTIONSSHOULDBE FOLLOWEDAND ENFORCED.
IF YOU SMELLGAS:
·
SHUTOFF GAS SUPPLYTOAPPLIANCE
EXTINGUISHOPEN FLAMES
·
IMMEDIATELY CALLYOUR GAS SUPPLIER
Instructions must be posted in a prominent location.All safety precautions must be taken in the event the user smells
gas. Safety informationcan be obtained from your local gas supplier.
1. Aseparate gas shut-off valve must be installed in the gas line ahead of the unit, as required by
2. LIGHTING:Follow the instructionson page 4.
3. At least 24 inches must be providedat the front of for servicing.
4. When installing, never enclose the bottom area of the unit with a raised curb or other construction that
would obstruct the flow of air into the unit.
5. This unit may be operated with 0 (sides and back) minimum clearance to non-combustible construction
in areas that are non-combustiblelocationsonly.
6. This installation must conform to local codes, or in absence of local codes to the
, latest edition. In Canada it must conform to current
(natural gas) or
7. The appliance and its individual shut-off valve must be disconnected from the gas supply piping system
during any pressuretesting of that system at test pressuresin excess of ½ psi (3.45 kPa).
8. The appliance must be isolated from the gas supply piping system by closing its individual manual shut-
off valve during any pressure testing of the gas supply piping system at test pressures equal to or less
then ½ psi (3.45 kPa).
9. This appliancemust be installed under a ventilationhood.
10. Do not obstruct the flow of combustionand ventilationair.
11. The area around this and any other gas appliancemust always be kept free and clear from combustibles.
Carefully unpack the open burner range and inspect immediately for shipping damages. Your open burner
range was shipped in a carton designed to give maximum protection in normal handling. It was thoroughly inspected
before leaving the factory and the carrier accepted and signed for it. File any claims for shipping damage or
irregularitieswith the carrier.
codes.
National Fuel Gas Code
ANSI Z223.1/NFPA 54
Natural Gas Installation Code
CAN/CGA B 149.1
CAN/CGA B 149.2 Propane Installation Code for Gas Burning
Appliances& Equipment.
MAIN SHUT-OFF VALVE
PRESSURE REGULATOR
Figure “A”
STANDING PILOT
All manuals and user guides at all-guides.com