background image

8.  BURNER OPERATION:

(a)  MAIN BURNER:

After the pilot burner is ignited, when heat is desired, turn gas cock dial to 'ON' () position and set the 
thermostat  dial  to  the  desired  temperature. The  oven  burner  flame  should  always  have  a  blue 
appearance. That indicates a good mixture of gas and air. When using LP gas, the flame will have a 
blue-yellow appearance.
Should the Burner fail to light, check to see if there is a problem with the gas supply. If there are other 
appliances on the same line, shut them off temporarily and see if the burner comes back on, or it 
fluctuates as other gas appliances are turned on and off. That would indicate overloading of the gas 
supply lines or a faulty gas pressure regulator. Contact an authorized Service Agency or your local 
Gas Supply Company.

(b)  AERATION AND BY-PASS FLAME ADJUSTMENT

:

Flame and air mixer adjustments and the By-Pass Flame adjustment for the Main Burner are done 
at  the  factory.  These  adjustments  are  sealed  before  the  oven  leaves  the  factory

.  Contact  an 

authorized Service Agency if you need help.

9.  THERMOSTAT CALIBRATION:

No attempt should be made to calibrate the thermostat because it is accurately calibrated and sealed by 
the manufacturer. 

Contact an authorized Service Agency if you need help

.

10. HEAT BAFFLE ASSEMBLY:

The  Heat  Baffle Assembly  distributes  the  heat  evenly  below  the  baking  deck.  It  must  be  in  good 
condition in order to be effective. A damaged Heat Baffle will adversely affect the oven performance. 
Check it periodically and replace as necessary.

II. OPERATING INSTRUCTIONS

NOTE: Only 

Pizza

 and 

Bread

 Products can have direct contact with Ceramic Decks. All other food 

products must be placed in a pan or containers to avoid direct contact with Ceramic Decks.

If gas odor is detected at any time, immediately shut-off the gas supply valve for the oven. Do not 
permit any open flames in the area of the oven. Immediately contact an authorized Service Agency 
or your local Gas Supply Company.

Initial heating of the oven must be done in a well-ventilated area as it may generate smoke or fumes. 
Over exposure to smoke or fumes may cause nausea or dizziness

3/8”-1/2”

Correct Flame

Figure #5

Figure #6

Thermostat

Pilot

Feed

Gas

Cock

Dial

Pressure 

Regulator

Pilot

Adjust
Screw

6

Summary of Contents for GP-51 Series

Page 1: ...lle NY 10801 914 576 0200 Phone 800 431 2745 US Canada 914 576 0605 Fax www bakerspride com WebAddress Note Only Pizza or Bread can have direct contact with ceramic decks All other food products must be placed in a pan or container to avoid direct contact with ceramic decks This equipment has been engineered to provide you with year round dependable service when used according to the instructions ...

Page 2: ...also to furnish forms for the consignee s claim When the oven arrives it should consist of A carton containing your new oven Two for a stacked unit Installation must conform with local codes and or to the latest edition of the ANS Z 223 1 National Fuel Gas Code in USA CAN CGA B 149 1 or 2 Installation Code in Canada This appliance must be installed by a competent person in accordance with the rule...

Page 3: ...ion and proper gas combustion is essential As a minimum observe the clearances detailed in Section 2 Provide adequate ventilation and make up air in accordance with local codes Fit the flue diverter See fig 1 and the flue transition piece into the rectangular opening located at top near the middle rear of the oven for installing the oven under a ventilation hood For Direct Venting Optional Draft H...

Page 4: ...gas units are not available in the European Community Countries a The appliance when installed must be electrically grounded in accordance with local codes and or the latest edition of the National Electric CodeANSI NFPA70 in USA Canadian Electric Code CSA C22 2 in Canada b In Europe appliance must be connected by an earthing cable to all other units in the complete installation and thence to an i...

Page 5: ... or a ULlisted vent cap at the end of the flue pipe Termination of the vent must be at least 2 feet above the highest part of the roof within 10 feet Ref American GasAssociation Catalog No Xh0474 7 MAIN BURNER SAFETY PILOT OPERATION The purpose of the safety pilot system is to lock the gas supply to the main burner at the combination valve if for any reason the pilot burner is not lit Oven should ...

Page 6: ...iceAgency if you need help 9 THERMOSTAT CALIBRATION No attempt should be made to calibrate the thermostat because it is accurately calibrated and sealed by the manufacturer Contact an authorized ServiceAgency if you need help 10 HEAT BAFFLEASSEMBLY The Heat Baffle Assembly distributes the heat evenly below the baking deck It must be in good condition in order to be effective A damaged Heat Baffle ...

Page 7: ...F 235 C to 500 F 260 C 4 RECOMMENDED OPERATING PROCEDURE It is very important that at the end of day s operation the gas cock dial of the Main Burner is turned to the pilot position leaving only the pilot burner ON overnight Preheating a Turn the gas cock dial of the main burner to the ON position b Preheat the oven for 1 to 1 hours at 50 F 10 C lower than your baking temperature Baking a When rea...

Page 8: ...IOR Clean the oven interior only when the oven is cold Use only the detergent solutions and cleaners that meet the national and or local codes a BAKING CHAMBER Clean the ceiling and the walls of the baking chamber with a mild soap and water solution Do not use oven cleaners caustic solutions or mechanical means as they will damage the interior aluminized surface b BAKING DECKS The baking decks are...

Page 9: ... Gas volume or gas pressure may be inadequate Thermostat or thermocouple may be defective Turn gas valve on Relight pilot Turn gas valve on Relight pilot Ensure that the tip of thermopile is in pilot flame Call local authorized Bakers Pride Service Agent Lower the thermostat setting and see if flame reduces in size Allow several hours for heat to regulate Call local authorized Bakers Pride Service...

Page 10: ... 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 43 44 47 45 46 47 48 49 50 51 53 52 42 54 55 56 Figure A Exterior Decks Burner Compartment Door Rod Interior Trim Page 2 of 4 Note When ordering ALWAYS specify Part Model Serial and type of gas 9 05 27 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 40 39 38 37 36 35 34 33 32 31 30 29 28 26 25 24 23 22 21 45 44 41 54 55 43 47 47 56 49...

Page 11: ...nstr Plate 29 U1172X Lighting Instruction Plate 13 S1149X Burner Door Handle w Screw 30 U1140X Minimum Clearance Plate 14 A4129X Control Door 31 U1044X Bakers Pride Name Plate 8 15 S1300X Top Door Handle w Screw 32 T8089X Leg Shelf 16 A5253X Door Handle Mount 33 S1022X 4 Casters w No Locks 17 A5330T Top Door 7 34 S1023X 4 Casters w Locks 35 A5258X Upper Breather Pan 39 A5301K Combustion Chamber Fr...

Page 12: ...45X Pilot Orifice L P 63 R3036X S S Pilot Tubing 45 64 L5032X Inspirator 2 65 R3075X Spud Assembly 2 w o Orifice 66 R3177A Burner Orifice N G Drill 30 67 R3077X Burner Orifice L P Drill 48 68 R3080X Blank Spud 2 For 2 Inspirator 69 M1296X Thermocouple T 46 Used w BGOR 70 M1392X Control Assy To Union N G BGOR 71 M1393X Control Assy To Union L P BGOR 72 M1005X Thermostat 73 S1056X Thermostat Knob F ...

Page 13: ...od Interior Trim Page 2 of 4 Note When ordering ALWAYS specify Part Model Serial and type of gas 9 05 GP 61 Counter Top Gas Oven 30 Pine Street New Rochelle New York 10801 914 576 0200 914 576 0605 1 800 431 2745 www bakerspride com fax US Canada web address BAKERS PRIDE 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 40 39 38 37 36 35 34 33 32 31 30 29 28 26 25 24 23 22 21 58 57 56 55 54 53 52...

Page 14: ...4 18 A5286X Top Door 14 2 A5229X S S Top Door Cover 7 19 A5276X Burner Door 3 A5231X Left Outer S S Side 20 S1014A 4 Leg Adjustable 4 A5232X Right Outer S S Side 21 S1050Y 30 Leg Painted Gray 5 A5233X Back Outer S S 22 S1212Y 30 Leg S S 6 A5234X Top Outer S S 23 S1241X 16 Leg S S 7 A5225X Bottom Trim 24 R3087X Flue Adapter 6 8 A5226X Control Panel 25 R3002X Direct Vent Draft Flue 6 9 A5235X Top Tr...

Page 15: ...fice 71 R3146X Burner Orifice N G Drill 30 72 R3091X Burner Orifice L P Drill 48 73 R3080X Blank Spud 2 For 2 Inspirator 74 M1296X Thermocouple T 46 Used w BGOR 75 M1265X Thermopile Used w BMVR 76 M1392X Control Assy To Union N G BGOR 77 M1393X Control Assy To Union L P BGOR 78 M1290X Control Assy To Union N G BMVR O S 79 M1291X Control Assy To Union L P BMVR O S 80 M1005X Thermostat 81 S1056X The...

Page 16: ...iod of THREE MONTHS The installation of these replacement decks is the responsibility of the purchaser The extended Cyclone door warranty years 3 through 5 is a parts only warranty and does not include labor travel milage or any other charges EXCLUSIONS Negligence or acts of God Thermostat calibrations after 30 days from equipment installation date Air and Gas adjustments Light bulbs Glass doors a...

Reviews: