background image

P. O. Drawer E / 161 Gatehouse Road / Sanford, Maine 04073 / USA

 

800-992-2537 / 207-324-8773 / Fax: 207-324-3869 / [email protected] 

 

 

 

398D003 Rev B 

i

 

 

 

 

INSTALLATION MANUAL  

 

Biological Containment Cabinet  

BD InoqulA          

 

MODEL 

BDINQ400 

 
 

 

 

 

 

 

Revision 

Date 

Description 

06/26/14 

Initial release 

07/28/14 

Revised and updated instructions  

08/18/14 

Revised and updated instructions page 4 

Summary of Contents for BD InoqulA

Page 1: ...73 Fax 207 324 3869 bakerco bakerco com 398D003 Rev B i INSTALLATION MANUAL Biological Containment Cabinet BD InoqulA MODEL BDINQ400 Revision Date Description A 06 26 14 Initial release B 07 28 14 Revised and updated instructions C 08 18 14 Revised and updated instructions page 4 ...

Page 2: ... 207 324 3869 bakerco bakerco com 398D003 Rev B ii TABLE OF CONTENTS I TOOL HARDWARE LIST BDINQ400 CABINET INSTALLATION 1 II PREPARING THE SA MODULE CABINET FOR INSTALLATION 2 III LIFTING AND PLACEMENT OF THE BDINQ400 5 IV MANUAL LIFTING OF THE BDINQ400 6 V ATTACHMENT OF THE BDINQ400 12 ...

Page 3: ...on Voltmeter Amp meter Consumables Teflon Tape Isopropyl Alcohol Glass Cleaner Paper towels or wipes Hardware fasteners 8 32 SS Hex Cap Nut 10553 8 32 SS Locking Hex Cap Nut 10559 8 SS Lock Washer 11307 8 SS Flat Washer 11279 8 Flat Washer UHMW 41583 10 32 UNF SS Button Socket Cap Screw 43030 10 SS Flat Washer 11281 20 x 2 1 2 SS Button Socket Cap Screw 43716 20 x 1 3 4 SS Button Socket Cap Screw ...

Page 4: ...unting screws located underneath the tabletop inside the bottom plenum Move the slide warmer forward in order to clear the area in front of the printer module Slide the printer to the rear of the instrument Note if this a field upgrade installation remove existing touch screen printer cover front shifter panel and all associated wiring for the touch screen Install new front shifter panel p n 20000...

Page 5: ...ated by dashed red lines for sealing between the bottom of the cabinet and the table top Step 4 Inspect the cabinet rear area to ensure that gasket material is properly attached Inspect threaded studs for damage or misalignment Align with holes in table top Template orientation With hole towards front 10 M6 threaded studs D gasket Align with holes in table top gasket Flat gasket ...

Page 6: ...e the inner access panel by removing the 1 4 hex head screws Step 6 Unscrew shipping screws attached to the viewscreen weight box and raise viewscreen Step 6 Attach front support bracket to the left and right view screen guide mounting holes prior to lifting Support bracket 561 8 1425 mm Outer side panel Inner access panel ...

Page 7: ... to cabinet and lift up slightly to verify balance Adjust as needed to get more even balance Step 4 Position cabinet over table top of SA chassis and carefully lower in place The cabinet s rear flange must fit between the slide plate warmer and shifter module cover Align cabinet mounting studs in rear with shifter module cover mounting holes then slide cabinet back against shifter module cover Nex...

Page 8: ...er Using two hands lower the front edge of the diffuser down Then while holding the edge firmly carefully pull it forward off its rear mounting studs and remove it from the cabinet work area Use caution to avoid damaging the HEPA filter Step 2 Remove the exterior and interior touch screen mount and label printer cover Step 3 Remove the two 1 4 20 button head screws from the lower left and right si...

Page 9: ...ot two fascia support arms on either side of the fascia away from the cabinet Lower the fascia panel onto the supports Step 5 Secure the weight box in its top position by raising the weight box and inserting the 1 4 20 hex head shipping screws Step 6 Unscrew cables on top of the weight box remove shipping screws and remove weight box Remove weight box guides Shipping screws Viewscreen cables attac...

Page 10: ... the four 5 16 hex nuts 2 each side that secure the electrical board Do not completely remove these Cut the wire ties securing cabinet wiring to the left and right of the cabinet front seal panel Step 9 Temporarily secure the electrical board to the wire tie cut outs located using ty raps 1 4 20 screws Wire tie cut out ...

Page 11: ...clear cable bracket Step 11 Lower control board and hang the top of the board off the lower screws This position will allow full access to the front seal panel hardware Step 12 Using a 7 16 ratchet or spin wrench loosen and remove the locknut and washer hardware from the upper viewscreen slides Top hardware Bottom hardware Upper viewscreen slide ...

Page 12: ...ge the gasket Step 15 Remove the screw holding the plastic clip securing the motor wiring Using a 3 8 spin wrench ratchet or drill with socket loosen and remove the bolt from the blower housing as shown Grasp the motor blower assembly with two hands and carefully slide out from the cabinet and rotate it so the motor is on the right Let it rest on the supply plenum Step 16 Disconnect each of the mo...

Page 13: ...rs to the brackets using 1 4 20 hex head screws Step 3 For ergonomic reason lift the cabinet onto a lift table that can be raised to the InoqulA table top height Position the lift table with cabinet to the right side of the SA module and lift the cabinet with four people over the SA table top while moving to the left When the cabinet is in the proper position remove the lifting aids from the each ...

Page 14: ...e top Step 2 Insert three 3 M6 x 30 mounting screws in the slots located in right side plenum Step 3 Attach all M6 mounting hardware for cabinet rear wall to shifter module Tighten all hardware including mounting screws between cabinet and SA chassis table top Step 4 Remove front fixture bracket from cabinet Mounting locations Table top Mounting locations ...

Page 15: ...o appropriate locations on the rear of the InoqulA PC Step 6 Install all removed cabinet parts in reverse order starting with blower front seal panel viewscreen and weight box touch screen mounts printer cover and right side access panel and outer side panel Step 7 Replace 1 4 20 button head screws in view screen guides and front dress panels with 1 4 20 thumb screws Towel guard Cable port for tou...