ES-787 Rev E
Page 2 of 6
This is important to maintain the ingress protection level and the integrity of the flameproof enclosure.
If the Installation is Intrinsically Safe, then check that the proper barriers are installed and the field wiring meets local and national codes for an IS
installation. Never install a device, which was previously installed without an intrinsically safe barrier, in an intrinsically safe system.
In non-incendive installations, check to ensure that all the electrical connections are made to approved circuits which meet local and jurisdictional
installation codes.
Verify that the markings on the label are consistent with the application.
3
FL AM EP R O O FAN D DU S T IGN IT IO N P R O O FR EQ U IR EM EN T S
General
The 3/4 inch NPT fittings must enter the housing at least five full turns.
The housing and cover threads should be clean and free of corrosion or other contaminants and foreign matter.
CableGlands
Certified cable glands are required based on the hazardous area the device is installed in. That is, the particular cable gland used must have the
same certification as the tick-box checked off on the label (see Section 6).
ElectrostaticDischarge
"X" Marking on label - Potential Electrostatic Charge Hazard – For safe operation use only wet cloth when cleaning or wiping device, and only
when local conditions around the device are free of potentially explosive atmospheres. Do not use dry cloth. Do not use solvent.
Dust
"X" Marking on label - Instruments installed in dusty hazardous area, Zone 20, 21 and 22, must be cleaned regularly to prevent the buildup of dust
layers on any surface.
To avoid the risk from electrostatic discharge, you must follow the guidance as detailed in PD CLC/TR 60079-32-1
For safe operation, use only wet cloth when cleaning or wiping the device. Cleaning must only be done when local conditions around the device
are free of potentially explosive atmospheres. Do not use dry cloth or any solvents.
4
IN T R IN S ICAL L Y S AFER EQ U IR EM EN T S
Div2
WARNING: EXPLOSION HAZARD – DO NOT DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN SWITCHED OFF OR THE AREA IS
KNOW TO BE NON-HAZARDOUS.
Equipm entGroupIICategory 1 (Zone0)
For operation in hazardous area category II 1, over-voltage protection of the electrical connections need to be installed according to EN 60079-14
Category II1 (Zone0)
“X” Marking on label - Since the SVI-II REMOTE MOUNT enclosure and cover both contain greater than 10% aluminum, care must be taken
during installation to avoid impacts or friction that could create an ignition source.
5
DES CR IP T IO N O FFL AM EP R O O FAN D IN T R IN S ICAL L Y S A FEM AR KIN GS
FrenchW arnings(CS A)
This requirement is in accordance with CSA C22.2 standards. These warnings are included on the primary labels above in English.
M anufacturersN am eandL ocation
DRESSER LLC, 12970 NORMANDY BLVD. JACKSONVILLE FL 32221 USA
P roductN am e:
“SVI
TM
-II Remote Mount”
L ogos/M arkings:
(Factory Mutual, US and Canada)