Masoneilan DSH Series Desuperheater Instruction Manual  |  4

Copyright 2020 Baker Hughes Company. All rights reserved.

Isolation Bypass Valve

To allow for in-line inspection, maintenance and removal of the 

desuperheater without service interruption, provide a manually 

operated shutoff valve on each side of the desuperheater and a 

manually operated throttling valve in the bypass line. The location 

of the downstream isolation valves requires special consideration 

in the case of the DSH Series Desuperheater as a result of the 

spray water injection system on the outlet of the Desuperheater 

valve. If the downstream isolation valve is close coupled to the 

Desuperheater, it will be difficult to properly control downstream 

temperature as the water injection becomes interrupted by the 

location  of  the  isolation  valve.  Please  contact  the  factory  for 

specific recommendations on a suitable downstream location of 

the isolation valve.

Flow Direction

The desuperheater must be installed so that the process fluid will 

flow through the desuperheater in the direction indicated by the 

flow arrow located on the body.

Welded Connections

Carefully follow the installation steps defined in the 

sections noted below prior to performing weld proce-

dures.

Carefully review the information in this section prior 

to welding any desuperheaters inline. Refer any 

additional questions to the local Baker Hughes Sales 

Office or Service Center.

Welding Process

Perform  welding  process  in  accordance  with  the  standard 

requirements  for  the  materials  and  weld  construction  of  the 

specific  desuperheater.  Apply  post  weld  heat  treatment  if 

required.

Post Weld Cleaning and Assembly

Inspect  the  body and components for  cleanliness and  surface 

condition.  Remove  any  foreign  materials,  such  as  weld  chips, 

slag or scale. Make sure there are no nicks, scratches, burrs or 

sharp corners on any sealing surfaces. Clean all gasket interface 

surfaces and reassemble using new gaskets to ensure sealing 

integrity.

Nozzles

Opening Nozzle Housing

Note: If the Desuperheater is shipped with the spray water 

nozzles installed, it is advisable to remove these critical 

devices during operations such as pipeline flushing and 

hydrostatic testing. Blank (blind) nozzles may be employed 

to separate hydrostatic test regions and protect important 

surfaces.

The valve nozzle housings must always be reassembled with a 

new set of gaskets. 
Before  disassembling,  make  sure  the  appropriate  gaskets  are 

available for replacement. 
Remove the nozzle flange nuts from the nozzle housing (Figure 

1).
Lift the nozzle housing flange from the nozzle housing.
Remove the nozzle flange gasket.
The nozzle holder may have a snug fit within the nozzle housing. 

For ease of removal of the nozzle holder, screw a bolt (per Table 

1) into the exposed threaded connection to provide a lifting point. 

Pull nozzle holder to remove from nozzle housing.
Remove nozzle gasket from the bottom of the nozzle housing.
If  installing  an  alternative  nozzle,  complete  the  following 

additional steps:
Install a new inner nozzle gasket in the gasket groove at the 

bottom of the nozzle housing.
Install the nozzle into the housing.
Install a new outer nozzle gasket in the gasket groove.
Mount the nozzle flanges and nuts to the housings.
Torque the nuts to the values indicated on the assembly drawing 

and to the required torquing sequence shown in Figure 1 in at 

least 6 equal torque steps (10%, 20%, 40%, 60%, 80%, and 

100% of the prescribed value) unless otherwise specified.

Nozzle C

v

Lifting Bolt Size

  

0.4

1/4”

  

0.8

3/8”

  

1.5

1/2”

  

3.0

3/4”

  

5.0

1”

             10.0

1-1/2”

Table 1 - Nozzle removal bolts

Summary of Contents for Masoneilan DSH Series

Page 1: ...Masoneilan DSH Series Desuperheater Instruction Manual Rev B Baker Hughes Data Classification Public...

Page 2: ...ICULAR REQUIREMENTS FOR OPERATION OF OTHER EQUIPMENT AT THE SITE THESE INSTRUCTIONS DO NOT PURPORT TO COVER ALL DETAILS OR VARIATIONS IN EQUIPMENT NOR TO PROVIDE FOR EVERY POSSIBLE CONTINGENCY TO BE M...

Page 3: ...3 Installation 3 Piping Cleanliness 3 Isolation Bypass Valve 4 Flow Direction 4 Welded Connections 4 Welding Process 4 Post Weld Cleaning and Assembly 4 Nozzles 4 Opening Nozzle Housing 4 Flushing Ope...

Page 4: ...hout Baker Hughes s written permission Please report any errors or questions about the information in this manual to your local supplier These instructions are written specifically for the Masoneilan...

Page 5: ...tional risks for assembly disassembly Proper techniques shall be followed to reduce the end users exposure to these hazards Personal protective equipment PPE and safety equipment shall be used in acco...

Page 6: ...ring spare parts the MODELAND SERIALNUMBERS indicated on the manufacturer s serial plate MUST BE GIVEN The serial plate is on the nozzle housing Unpacking Care must be exercised when unpacking the pro...

Page 7: ...ts for cleanliness and surface condition Remove any foreign materials such as weld chips slag or scale Make sure there are no nicks scratches burrs or sharp corners on any sealing surfaces Clean all g...

Page 8: ...gasket into the bottom of the nozzle housing Securely install the nozzle holder into the nozzle housing The nozzle holder should fit flush with the housing surface otherwise remove the nozzle holder a...

Page 9: ...rom coming loose due to the thermal expansion caused by the steam line This assembly should not be disassembled and must be purchased as a complete assembly 4 Inspect the inside of the nozzle holder t...

Page 10: ...Baker Hughes if cracks or damage is discovered Figure 3 External inspection Water Connection Branch Outlet Field Weld Water Ring Cap Down Tube Inlet Field Weld Nozzle Housing Branch Liner Pin Interna...

Page 11: ...s Desuperheater Item No Description 1 Body 2 Nozzle S A 3 Nozzle Holder 4 Nozzle Gasket 5 Nozzle Flange Gasket 6 Nozzle Housing Flange 7 Nozzle Flange Stud 8 Nozzle Flange Nut 9 Flow profiler Lo dB pl...

Page 12: ...f Baker Hughes Company Other company names and product names used in this document are the registered trademarks or trademarks of their respective owners BHMN DSH IOM 33464B 0820 08 2020 Tech Field Su...

Reviews: