background image

 

 

© 2021 Baker Hughes Company. All rights reserved. 

Masoneilan 77-80H/00-80H Air Valve Instruction Manual | 7

 

1. Outline 

The 77-80H, an air valve that consists of a combination of pilot valve and three-way valve, 
is a high-capacity "set pressure control" type three-way valve.  

Besides this, there is the 00-80H, the so-called three-way valve - the 77-80H from which 
the pilot valve is removed.  

In  case  a  plurality  of  77-80H  valves  are  needed,  use  one  77-80H  valve  and  00-80H 
valves for the rest and connect the outlet pressure of the 77-80H's pilot valve to "SIG" of 
each 00-80H valve. By so doing, not only piping is simplified but also change-over can be 
made simultaneously. 

 

2. Specification 

 

Item 

Standard 

Option 

Max  Operating 
Pressure 

Body 

880 kPa 

 

Signal 

1030 kPa 

 

Set Pressure Range 

100 

– 700 kPa 

 

Hysteresis 

<= 34 kPa 

 

Cv Value 

IN 

→ OUT 

4.56 

 

OUT 

→ EXH. 

4.25 

 

Connection 

IN, OUT, EXH. 
Ports 

Rc1/2 

½ NPT 

SIGNAL Port 

Rc1/4 

¼ NPT 

Operating Temperature Range 

-30 to +70

 

-18 to +100°C (High Temp) 
-49 to +80°C   (Low Temp) 

Housing Material 

Aluminum Alloy 

 

 

3. Installation 

Prior  to  installing,  clean  all  lines  thoroughly  to  remove  all  dirt,  scale  or  other  foreign 
matter.  

Install the air valve as near the actuator as possible, holding the number of connections 
to a minimum, so that the air flows in the direction indicated by the marks, 

”IN" and "OUT" 

on the underside of valve body. There are two "EXH" ports. Use the necessary one and 
pipe plug the other.  When the valve is to be used as a lock-up valve, the both ports must 
be pipe plugged.  

The signal pressure piping should be made by connecting the supply pressure directly to 
"SIG. IN"  so that when the air pressure drops below the set pressure or disappears the 
air valve operates to close "IN" and connect "OUT" and "EXH

”.  

 

 

Do not use for air pressures exceeding 880 kPa.  

Be careful not to take the signal pressure from near the "IN” side of body because 
due to the large capacity of the air valve this gives rise to a change in signal air 
pressure, thereby causing hunting.  

 

 

Summary of Contents for Masoneilan 77-80H Series

Page 1: ...Baker Hughes Data Classification Public Masoneilan 77 80H 00 80H Series Air Valve Instruction Manual Rev A...

Page 2: ...REQUIREMENTS FOR OPERATION OF OTHER EQUIPMENT AT THE SITE THESE INSTRUCTIONS DO NOT PURPORT TO COVER ALL DETAILS OR VARIATIONS IN EQUIPMENT NOR TO PROVIDE FOR EVERY POSSIBLE CONTINGENCY TO BE MET IN...

Page 3: ...without prior notice The information contained in this manual in whole or part shall not be transcribed or copied without Baker Hughes s written permission Please report any errors or questions about...

Page 4: ...he equipment otherwise it may cause malfunction of the valve Air Source Use clear air Do not use compressed air that contains chemicals synthetic oil based on organic solvents or corrosive gas or othe...

Page 5: ...ve controller or any other equipment will not operate suddenly Gradually extract the pressure of air in all the operating lines and disconnect the operating lines only after the air is entirely extrac...

Page 6: ...__________________________________________ 7 2 Specification __________________________________________ 7 3 Installation____________________________________________ 7 5 Maintenance ___________________...

Page 7: ...Port Rc1 4 NPT Operating Temperature Range 30 to 70 18 to 100 C High Temp 49 to 80 C Low Temp Housing Material Aluminum Alloy 3 Installation Prior to installing clean all lines thoroughly to remove a...

Page 8: ...as follows A Shut off the supply pressure B Return the adjusting screw to its former position and loosen the spring Disassembling Procedure Remove four screws 25 and remove O Ring 15 housing S A rang...

Page 9: ...ny All rights reserved Masoneilan 77 80H 00 80H Air Valve Instruction Manual 9 INLET PRESSURE 880 kPaG 125 psiG SET RANGE 35 700 kPaG 5 100 psiG Rc1 4 NPT1 4 SIGNAL Rc1 2 NPT1 2 EXHAUST Rc1 2 NPT1 2 O...

Page 10: ...r Hughes 2021 Baker Hughes Company All rights reserved INLET PRESSURE 880 kPaG 125 psiG SIGNAL PRESSURE 35 700 kPaG 5 100 psiG Rc1 4 NPT1 4 SIGNAL Rc1 2 NPT1 2 EXHAUST Rc1 2 NPT1 2 OUTLET Rc1 2 NPT1 2...

Page 11: ...hughes com Copyright 2021 Baker Hughes Company All rights reserved Baker Hughes provides this information on an as is basis for general information purposes Baker Hughes does not make any representati...