BAK Thermoplastic Welding Technology AG
7
red/brown
black/white
blue/green
1
4
2
3
8
7
6
5
9
11
10
DEVICE DESCRIPTION
1. Power supply cord
2. Blower ON – OFF
3. Heater ON – OFF
4. Removable handle
5. Potentiometer for air volume
control
6. Potentiometer for temperature
control
7. Type plate (back side of the de-
vice)
8. Heating element tube
9. Air intake
10. Installation regulator (optional)
11. Six M5 drilled and tapped holes
for fixing into installation (Di-
mensions on the underside of
the device)
PINOUT SCHEME FOR SPECIAL DESIGNS
Control cable for external temperature control:
-
digital signal (PWM 10-24 V
DC
max. cycle time 1 se-
cond)
+ = brown
- = white
Control cable for external potentiometer for temperature or
speed control:
Control cable for external speed control:
-
digital rpm= 15V
DC
, l/max = 10mA; PMW/1-
10KHz/50-100% (50% minimum air-flow)
-
analogue 5-10V
DC
; (5V
DC
= minimum air-flow)
+ = green
- = white
Warning:
For analogue and digital speed control, the minimum air-flow must be guaran-
teed when
the hot-air blower is running.
Signal line for external speed indicator:
-
1 impulse per revolution
-
open collector exit
+ = brown
- = white
Compensating line for 'K' type internal thermocouple:
+ = green
- = white