![BAK Thermoplastic Welding Technology RION Operating Manual Download Page 4](http://html1.mh-extra.com/html/bak-thermoplastic-welding-technology/rion/rion_operating-manual_467491004.webp)
4
BAK Thermoplastic Welding Technology AG
OPERATING CONDITION
Maintain the maximal allowed impedance Zmax. =0.264+j0.165 and if necessary
consult the power supply company.
As required, push fit the correct nozzle or reflector.
Connect the tool to the mains.
Adjust the hot air temperature by use of potentiometer (3).
Switch on (2) and let heat up for about 5 min.
CHANGE OF NOZZLES
Allow the tool to cool down before changing nozzles or use only combination
pliers.
Do not touch the hot nozzle and make sure to put it only on a heat resistant surface,
because of fire hazard.
The nozzles are easily pushed on to the tapered element housing (7) and are
secured by fastening the screw on the clamp.
TECHNICAL DATA
Technical Data
Rion
Voltage
V
230
120
Frequency
Hz
50 / 60
Power consumption
W
1600
Temperature
°C
20 – 700 stepless controlled
Max. air flow
l/min
approx. 250
Dimensions
mm (L x W x H)
100 x 340, handle 56
Weight with 5 m cable
kg
1.3 with 3m cord
Protection class
IP20
Conformity symbol
Protection type I
Electrical safety
double insulated
MAINTENANCE
Airfilter (5) should be cleaned with a brush.
Check power supply cord (1) and plug for any possible electrical or mechanical
damage.