eQUipMent FeAtUReS, cOnt’D
PROGRAMMING FILTER CYCLES:
You may choose to filter the spa 1, 2 or 3 times per day as required to keep the water clean
and sanitary. Press and hold the Pump Key for 5 seconds. The current setting will be displayed as F1, 2 or 3. Use the Up & Down
Temperature Arrow keys to increase or decrease the frequency of the filtration cycles per day. The filter cycle is now set. To start
a filter cycle immediately, press the Pump key. The cycles will repeat every 8, 12 or 24 hours within a 24-hour period starting from
the time programmed. It is recommended to schedule the filtration cycles so they do not interfere with sleeping hours.
PROGRAMMING FILTER CYCLE DURATION:
You may choose to filter your spa 1–8 hours per cycle as requried to keep
the water clean and sanitary. Press and hold the Light Key for 5 seconds. The current duration of the filter cycle will be
displayed as D1–8. Use the Up & Down Temperature Arrow keys to increase or decrease the duration of the filter cycle. The
duration is now set. To start a filter cycle immediately, press the Light key while the duration setting is still displayed.
HEATER OPERATION:
When the water temperature drops 1ºF lower than the desired temperature, the heater will be
turned on until the water temperature reaches the desired temperature plus 1ºF. The Heater On Indicator will appear on the
function panel when it is on. The Heater On Light Indicator will blink on the function panel whenever there is a call for heat
and the heater has not yet been activated.
FREEZE PROTECTION:
When the system senses cold temperatures, it will automatically engage the freeze protection mode
for a monitoring period of 24 hours. During this time, the pump will operate for 1 minute every 2 hours to circulate warm water
through the plumbing. When the pump is running due to this feature, the Filter Cycle Indicator on the spaside panel will blink.
Filter Cycles will operate as determined by the programing and will not be affected by the Freeze Protection Mode.
HIGH TEMPERATURE PROTECTION:
If the water temperature exceeds 112ºF at the High Temperature probe, the system
will display the message HL and will turn the heater off. After the water temperature has cooled down, pressing any key on
the spaside panel control will allow the system to restart. If the spa water temperature does not seem to be elevated, the
HL reading may have been caused by poor water flow or electrical line interference (e.g. thunderstorms, voltage surges,
etc.). Simply reset and monitor the system. See Troubleshooting, page 14.
NOTE: The Freeze Protection Circuit is in
effect at all times that there is power applied to the system and will automatically engage if needed.
DEFAULT SYSTEM OPERATIONS:
When power is applied, or there is a temporary loss of power, the system will initiate
it’s last programmed temperature setting. If a power loss condition is experienced, the spaside display will blink until any key
is pressed. This feature is to let the user know that a power failure has occurred.
SETTING FAHRENHEIT AND CELSIUS DEGREES:
Press and hold the light key for 5-seconds, the display will change to
either setting. When the desired display is shown the display has been set and nothing else must be done.
NOTE: If the
spa is being used during the filter cycle, the cycle will be suspended for a period of 40-minutes.
IF A POWER OUTAGE SHOULD OCCUR:
It will be necessary to reprogram the filter cycle start time. The temperature
setting will be retained.
eQUipMent MODULe
Your Baja Spa is equipped with exclusive “Smart Cords”. These cords have internal illumination to let you know that power is being
supplied to the components connected to them. This is a helpful troubleshooting feature should a problem with a component arise.