SPORTUB II 1057-58 Controller Operations

JET1 

 - The JET1 button is used to turn the pump on or off at selected speeds.  The first press will 

turn the pump to LOW speed.  The second press will change the pump to HIGH speed.  The third 
press will turn the pump off or return to a heat or filtration mode (see note).  A built in timer will shut 
the pump off 20 minutes after it has been started unless the user does so manually.  When the 
pump is on, the "Jets On" indicator will appear above the JET1 button.

  
 Note: You may not be able to turn the pump off if it has started a filtration cycle or if the spa is calling for additional 
heating.  This is easily identified by observing the status of the "Heater On" indicator light or the "Filter Cycle" indicator 
light. 

JET2 

 - The JET2 button is used to turn the JET2 booster pump on or off.  The first press of the 

JET2 button will start the booster pump.  A second press will turn the booster pump off.  The JET2 
booster pump will automatically turn itself off after 20 minutes.  When the JET2 booster pump is 
on, the JET2 indicator light will appear above the JET2 button.

LIGHT  

- The LIGHT button is used to turn the light on or off.  The first press of the LIGHT button 

will turn the light on.  The second press of the button will turn the light off.  The light will 
automatically turn itself off after 2 hours.  When the light is on, the indicator light will appear above 
the LIGHT button.

TEMPERATURE PROGRAM 

 - The temperature program button is used to set the desired water 

temperature.  Press and hold this button to increase or decrease the desired temperature setting.  
Release and press again to increase/decrease to the desired temperature setting.  The 
temperature can be adjusted in 1°F increments from 59°F to 104°F (or 15°C to 40°C).  The desired 
temperature setting will remain in the display box for 5 seconds as confirmation of the new setting.  
After 5 seconds, the display will show the current water temperature.

  
 Note:  The temperature program indicator will appear to indicate that the temperature in the display is the desired 
programmed temperature and not the actual water temperature.

Note:  A power outage to the system will erase any programmed settings.  If  a power outage 

should occur, it will then be necessary to re-program the system.  

Filtering default is 120 

minutes, twice a day.  Temperature default is 100 degrees.

10

Programming Number of Filter Cycles:

You may choose to filter the spa 1, 2 or 3 times daily as required to maintain clean water.  To view 
the current number of filter cycles, 

press & hold

 the Pump1 button for 5 seconds.  

The current number of filtration cycles will be displayed. This setting can be modified by holding 
down the Up/Down button until the desired number of cycles is shown.  A simultaneous 

press & 

hold

 of the Pump1 & Up/Down button for an extra 5 seconds  will start a new filter cycle.

Programming Cycle Duration

You may choose to filter spa 60, 120, 180 or 480 minutes per cycle as needed to maintain filtered 

water.  To view the current length of each filter cycle, 

press & hold

 the Light button for 5 seconds.   

The current length of each filtration cycle will then be shown.  

This setting can be modified by holding the Up/Down button until the length of each cycle is shown.  
A simultaneous 

press & hold

 of the Pump1 & Light button for 5 seconds more will start a new filter 

cycle.

Summary of Contents for sportub series

Page 1: ...nt Safety Instructions Please read and follow all instructions before installing operating or enjoying your spa Please refer to the operational video that is supplied with spa Save these instructions for future reference REV03 05 Spa Owner s Spa Owner s Manual Manual FOR FOR HOTTUBS COM ...

Page 2: ...ser William II Mineral springs in those days were very similar to today s spas in that both were used for therapeutic and recreation purposes The ancient Romans after a day of conquering the world retreated to the pleasures of their mineral springs In fact many well preserved mineral springs built by the ancient Romans still exist today in places as far off as Bath England and Tiberias Israel Afte...

Page 3: ...stalled at least 5 ft 1 5 m from spa water See GFCI Warning pg 4 6 DANGER Risk of Accidental Drowning Extreme caution must be exercised to prevent unauthorized access by children To avoid accidents ensure that children do not use this spa unless they are supervised at all times 7 DANGER Risk of Injury The suction fittings in this spa are sized to match the specific water flow created by the pump S...

Page 4: ... the risk of injury a The water in a spa should never exceed 40 C 104 F Water temperature between 38 C 100 F and 40 C 104 F are considered safe for a healthy adult Lower water temperatures are recommended for young children and when spa use exceeds 10 minutes b Since excessive water temperatures have a high potential for causing fetal damage during the early months of pregnancy pregnant or possibl...

Page 5: ... Push the reset button on the GFCI and the product should operate normally If the product fails to operate in this manner there is a ground current flowing indicating the possibility of an electrical shock Disconnect the power until the fault has been identified and corrected SAFETY INSTRUCTIONS 120 VOLT OZONE GENERATOR 4 120 VOLT OZONE GENERATOR INSTALLATION optional The Sportub series are equipp...

Page 6: ...any electrical wires 7 In selecting the ideal outdoor or indoor location for your spa we suggest you take into consideration the following a The view you will have from the spa b The proximity to your home for changing and or shelter this is very important in cold weather c A sheltered environment providing protection from wind and weather if needed d The overall enhancement of your yard or room e...

Page 7: ...rcuit The heater will provide 1100 watts 1 1 kw of heat when the pump is operating in low speed and thermostat is calling for heat Under no circumstances should an extension cord be used Use of an extension cord will seriously degrade the performance of the equipment module and can create an electrical hazard Use copper conductors ONLY 5 MINIMUM WIRE SIZE FOR GROUND 10 AWG Refer to local codes for...

Page 8: ...7 ...

Page 9: ...r water leaks 6 Familiarize yourself with controller operations Pages 9 10 7 Apply power to the Equipment Module 120 Volt Units Plug cord into dedicated 15 amp outlet 240 Volt Units Turn the main disconnect switch to the ON position 8 Push the JET button located on the topside SPORTUB control panel The pump will now operate at high speed 9 Set desired temperature IMPORTANT NOTE It is very importan...

Page 10: ...Temperature Program point has returned to the default value JETS KEY The Jets key is used to turn the pump on or off at selected speeds The first press will turn on the pump HIGH speed the second press will change the pump to LOW speed the third press will turn the pump off or return to a heat or filtration mode see note A built in timer will shut the pump off 20 minutes after it has been started ...

Page 11: ...sired temperature setting Release and press again to increase decrease to the desired temperature setting The temperature can be adjusted in 1 F increments from 59 F to 104 F or 15 C to 40 C The desired temperature setting will remain in the display box for 5 seconds as confirmation of the new setting After 5 seconds the display will show the current water temperature Note The temperature program ...

Page 12: ...E INTERNAL SYSTEM TIME PATTERN Desired Filter Cycles Programming Time Filtering Time 1 Cycle per 24 Hour Period 8 00 PM 8 00 PM 2 Cycles per 24 Hour Period 8 00 PM 8 00 PM 8 00 AM 3 Cycles per 24 hour Period 2 00 PM 10 00 PM 6 00 AM 2 00 PM Note The easiest way to change the internal system time pattern is to simply TURN OFF ALL POWER to the spa for 10 ten seconds and then promptly start your prog...

Page 13: ... CONSULT YOUR NATURE2 OWNER S MANUAL BEFORE INSTALLING PURIFICATION SYSTEM ALWAYS CONSULT YOUR DEALER FOR RECOMMENDATION AND MAINTENANCE DETAILS FILTER REMOVAL JET OPERATION Open air control fittings when in HIGH speed Jets mode Turn outer ring to direct flow from TurboStream to Magna Jets Each TurboStream jet controls bucket seat jets Pull tab and turn lock ring counterclockwise Remove filter lid...

Page 14: ...t Re attach clear hose completely over barbs and re secure with clamp Complete cabinet installation TO DRAIN SPA MAKE SURE EQUIPMENT IS IN OFF POSITION Simply remove the drain cap Attach a garden hose to threads Turn front face counter clockwise and pull outwards There should be a slow but steady flow of water which originates from the gravity drain located in bottom of the Baja spa CABINET DRAIN ...

Page 15: ...ANCE SCHEDULE 14 CLEANING THE FILTER Your Baja Spa comes complete with a 50 Sq Ft filter cartridge that is designed to work under pressure With normal use this filter should be removed a minimum of once every 30 days or anytime you notice an appreciable decrease of the flow from the spa jets You should take time to clean the filter TO CLEAN THE FILTER 1 TURN OFF THE POWER 2 REMOVE THE COVER FROM T...

Page 16: ...ANY ABRASIVE CLEANERS as they can scratch or dull the brilliant acrylic surface Your insulated cover can be cleaned with a non abrasive household cleaner A non silicone based vinyl restorer will help protect the surface from sun damage REGULAR SPA MAINTENANCE 15 If the spa is to be left unused for an extended period of time in areas where freezing temperatures DO NOT OCCUR it may be desirable to t...

Page 17: ...17 TROUBLESHOOTING Air lock plumbing system Bleed the system see start up procedure page 8 Restricted flow ...

Page 18: ...ezing temperatures PRESSURE SWITCH To assure proper heater operation a water pressure switch has been installed to monitor the system If 3 flashing dots appear below the temperature in the LED window this indicates the need for system service Refer to the advanced troubleshooting guide available from your spa retailer or contact a service technician to correct the problem HIGH TEMPERATURE PROTECTI...

Page 19: ...rough the heater Readjust pressure or flow switch With Pump Off a If 3 flashing dots appear while the pump is off the pressure or flow switch is activated although no water is flowing through the heater Readjust pressure or flow switch System Error LED Illuminated a This is an indication of an Over Temperature condition Ensure that the High Limit temperature sensor is properly connected to the pri...

Page 20: ...wner Spa Condition Headrest Condition Care _________________________ _________________________ Spa Cover Condition Care _________________________ _________________________ Skirting Condition Care _________________________ _________________________ Overall Spa Appearance _________________________ _________________________ _________________________ Other_______________________ ______________________...