background image

1  

ESSENCIA DROP-IN - installation

www.bainultra.com 

Some products, specifications, and services mentioned in this manual are described in pending patent applications or are protected by patents.

ESSENCIA

® 

 COLLECTION - DROP-IN MODELS

IMPORTANT SECURITY INSTRUCTIONS 

IMPORTANT SAFETY INSTRUCTIONS  

PERTAINING TO RISKS OF FIRE, ELECTROCUTION OR PERSONAL INJURY

READ AND FOLLOW ALL INSTRUCTIONS   •   SAVE THESE INSTRUCTIONS

THIS DOCUMENT SUPERCEDES THE INSTALLATION INSTRUCTION IN THE OWNER’S MANUAL. 

WARNING

•  Risk of hyperthermia; people using medication and/or having an adverse medical history should consult a physician  

before using a Hydro-thermo massage

®

 bathtub equipped with a heater.

•   Risk of hyperthermia and possible drowning: do not use a Hydro-thermo massage

®

 bathtub equipped with heater  

immediately following strenuous exercise. 

•   Risk of fetal injury; pregnant or possibly pregnant women should consult a physician before using a Hydro-thermo  

massage

®

 bathtub equipped with a heater. 

•   Risk of accidental injury or drowning; do not use drugs or alcohol before or during the use of a Hydro-thermo massage

®

 

bathtub equipped with a heater. 

•   Use this unit only for its intended purposes or as described in this manual. Use only accessories or devices recommended  

by the manufacturer. 

•   Risk of hyperthermia and possible drowning. Check and adjust water temperature before use. Water temperature  

exceeding 100ºF (38ºC) may be injurious to your health. 

•   To reduce the risk of injury, as with any other conventional bath, do not allow children or physically impaired people  

to use this unit unless they are closely supervised at all times.

•  To avoid injury, exercise care when entering or exiting the Thermomasseur

®

.

•   The Geysair (option) should always be connected to the hot water intake. If it is not the case, then, the Geysair option 

should be deactivated via the bath control.

RISK OF ELECTRICAL SHOCK

•  Disconnect electric power before servicing.

•   Do not permit electrical appliances (hair dryer, lamp, telephone, radio, television, etc.) within 5’ (1,5 m) of the Thermomasseur

®

.

•   Before using the Thermomasseur

®

, its exterior construction (podium or skirting) should be finished so that a bather cannot 

accidentally come in contact with electrical components (turbine and power module). 

•  For indoor use only.

Summary of Contents for ESSENCIA OVAL 7236

Page 1: ...7438 INSTALLATION INSTRUCTIONS ADDENDUM to ESSENCIA INSTALLATION INSTRUCTIONS IMPORTANT INFORMATION FOR THE INSTALLER AND THE OWNER This document should always be accompanied by the ESSENCIA INSTALLA...

Page 2: ...N DROP IN MODELS INSTALLATION INSTRUCTIONS TABLE OF CONTENT IMPORTANT SAFETY INSTRUCTIONS 1 PARTS TOOLS 3 SITE PREPARATION 5 INSTALLATION DROP IN WITH REMOTE MOUNTING OF TURBINE ESSENCIA OVAL 7236 DES...

Page 3: ...e drugs or alcohol before or during the use of a Hydro thermo massage bathtub equipped with a heater Use this unit only for its intended purposes or as described in this manual Use only accessories or...

Page 4: ...90 C Canada only for permanently connected units A green colored terminal or a wire connector marked g gr ground or grounding is provided within the terminal compartment not applicable if unit suppli...

Page 5: ...ng nut 1 C Strainer 1 D Rubber seal 1 E PVC Wired drain shoe 1 F PVC Piping 1 1 2 x2 1 G PVC Tee Connector 1 1 2 F F 1 DESCRIPTION QTY H Plated drain clicker 1 I Strainer 1 J Rubber seal 1 K Brass dra...

Page 6: ...ESSENCIA COLLECTION DROP IN MODELS INSTALLATION INSTRUCTIONS B C D A PARTS TOOLS REQUIRED STANDARD PARTS THERMOMASSEUR DESCRIPTION QTY A Turbine 1 B MiaPlus Control Design 7438 1 C MiaMulti Control Ov...

Page 7: ...erneath the bath can support 1500 lb 680 kg The bath may sit directly on the floor The bathtub can also sit on a concrete bed In that case it is recommended to isolate the concrete between two plastic...

Page 8: ...653 ESSENCIA COLLECTION DROP IN MODELS INSTALLATION INSTRUCTIONS PLUMBING INTALLATION TEMPLATES FLOOR LAYOUT FOR PIPES AND ACCESS ESSENCIA OVAL 7236 ESSENCIA DESIGN 7438 DROP IN INSTALLATION WITH REMO...

Page 9: ...ent applications or are protected by patents ESSENCIA COLLECTION DROP IN MODELS INSTALLATION INSTRUCTIONS 1 PLUMBING ESSENCIA OVAL 7236 Assembly of the waste overflow DROP IN INSTALLATION WITH REMOTE...

Page 10: ...l 2017 BainUltra Inc All rights reserved 45200653 ESSENCIA COLLECTION DROP IN MODELS INSTALLATION INSTRUCTIONS DROP IN INSTALLATION WITH REMOTE MOUNTING OF TURBINE ESSENCIA OVAL 7236 DESIGN 7438 1 PLU...

Page 11: ...installation template DROP IN INSTALLATION WITH REMOTE MOUNTING OF TURBINE ESSENCIA OVAL 7236 DESIGN 7438 Box Structure Installation Template IF NEEDED make an opening of sufficient dimension in the...

Page 12: ...1 16 0 2cm considering the thickness of the glue of the finishing Adjust the height of the bath to the floor if necessary The bath is molded with a slope towards the drain If the bathtub is levelled a...

Page 13: ...rawn on the installation template at 1 2 5 cm from the outside edge of the bath area Keep an access to perform electrical plumbing connections Keep minimum 22 x18 55cmx46cm access to perform electrica...

Page 14: ...bath during installation Connect the drain Perform a leak test before completing the box installation Once the bath is placed on the floor it is recommended to leave a clearance of 1 16 0 2cm between...

Page 15: ...OVAL 7236 DESIGN 7438 5 ELECTRONIC CONTROL INSTALLATION MIAPLUS DESIGN 7438 MIAMULTI OVAL 7236 PAGE 15 6 REMOTE MOUNTING OF TURBINE PAGE16 7 REMOTE MOUNTING OF TURBINE AIR PIPE THERMOMASSEUR PAGE 17...

Page 16: ...MODELS INSTALLATION INSTRUCTIONS DROP IN INSTALLATION WITH FACTORY INSTALLED TURBINE ESSENCIA OVAL 7236 A Turbine B WarmTouchShell C Chromatherapy LED D MiaPlus E MiaMulti F AromaCloud C A D E F B FO...

Page 17: ...h the ground and its clearance with the opening on top of the box Use shims if necessary and attach them to the ground WARNING Check the spacing from the bottom of the deck to the top of the plywood p...

Page 18: ...e box opening for the final installation of the bath on the floor A ESSENCIA DESIGN 7438 DRAIN CONNECTION B DECK OF THE BATH CLEARANCE 4 10cm minimum WARNING Leave the plastic film on the bath and pla...

Page 19: ...er in the bath during installation Cut the bath contour on the support panel according to the EXTERIOR contour line drawn on the installation template AND LEAVE an additional 1 4 0 6cm of clearance Ch...

Page 20: ...on the top panel following the UNDERMOUNT line of the installation template Apply a bead of silicone on the contour of the bath to make sure the bottom of the box is sealed 5 ELECTRONIC CONTROL INSTA...

Reviews: