PowerTop V3 Manual www.baintech.com.au
PowerTop V2 User Operation Manual
If you require faster charging we recommend using a 20A (maximum) charger suited for Gel batteries with the following
voltage set points:
•
Bulk 14.2V
•
Float 13.7V
The external charger is to be connected to the
Grey
Anderson connector labeled 50A Battery Output.
CHARGING
Important note: PowerTop must be ON for charging (See page 5 for on/off location)
7
Internal AC charger
The PowerTop comes with an internal 6.6A AC charger.
The charger operates when the AC plug is connected into the
unit.
When charging with the inbuilt AC charger:
1) Disconnect PowerTop unit from all loads and turn OFF unit
2) Connect the AC plug from 240V AC source to the unit.
3)Turn ON the PowerTop Unit- Mains LED will turn ON- Leave
charging until full.
FAST CHARGING
Important note: PowerTop must be ON for charging (See page 5 for on/off location)
If you require faster charging we recommend using a 20A (Maximum 25A) charger suited for AGM batteries with the following
voltage set points:
•
BOOST 14.2V
•
FLOAT 13.7V