background image

INTRODUCTION

GLOSSARY OF TERMS AND ABBREVIATIONS

1 - 4

  

I-E96-425A

®

GLOSSARY OF TERMS AND ABBREVIATIONS

Table 

1-2

 contains the glossary of terms for this manual. 

NOMENCLATURE

Table 

1-3

 contains the modules and equipment that can be

used with the NIAC03 module:

SPECIFICATIONS

Table 

1-4

 contains the specifications for the NIAC03 module.

Table 1-2.  Glossary of Terms and Abbreviations

Term

Definition

Analog

Continuously variable as opposed to discretely vari-
able.

RTD

Resistance temperature detector. A sensing device 
that changes resistance within a temperature range.

Slave Module

One of a series of modules designed to perform high 
or low level operations as directed by a master mod-
ule.

TMU

Termination mounting unit. A card cage that provides 
housing for INFI 90/Network 90

®

 termination mod-

ules.

® .

® Network 90 is a registered trademark of Elsag Bailey Process Automation.

Table 1-3.  Nomenclature

Nomenclature

Description

IMASM03

Analog Slave Module

NKTM01

Cable, Termination Module (Ribbon)

NKTU02

Cable, Termination Module (PVC)

NKTU12

Cable, Termination Module (non-PVC)

NTMU01

Termination Mounting Unit (Rear Mount)

NTMU02

Termination Mounting Unit (Front Mount)

258436_1

Cable retaining kit used when a round cable con-
nects to the termination mounting unit.

Table 1-4.  Specifications

Property

Characteristic/Value

Power Requirements

No power is required by the NIAC03 module. 

Mounting

Slides into a single slot in the NTMU01 Termination Mounting Unit or NTMU02 
Termination Mounting Unit.

Summary of Contents for Infi 90 NIAC03

Page 1: ...Process Control and Automation Solutions from Elsag Bailey Group E96 425 Analog Input Calibration Module NIAC03...

Page 2: ...UIPEMENTS LECTRONIQUES SONT SENSIBLES AUX PERTURBATIONS PAR FR QUENCE RADIO DES PR CAUTIONS DEVRONT TRE PRISES LORS DE L UTILISATION DU MAT RIEL DE COMMUNICATION PORTATIF LA PRUDENCE EXIGE QUE LES PR...

Page 3: ...nputs for the IMASM03 Analog Slave Module This manual explains how to install and use the NIAC03 mod ule on the INFI 90 Strategic Process Management System It has sections that describe the setup and...

Page 4: ...gh 1 5 Original 2 1 through 2 5 Original 3 1 Original 4 1 Original 5 1 Original A 1 Original Index 1 Original NOTE On an updated page the changed text or table is indicated by a vertical bar in the ou...

Page 5: ...slot Failure to do so could result in damage to the module p 2 4 4 1 AVERTISSEMENTS D ORDRE G N RAL Environnement de l quipement Ne pas soumettre les composants une atmosph re corrosive lors du transp...

Page 6: ...ATION 2 2 Jumper Settings 2 2 Cable Installation 2 2 Module Installation 2 5 SECTION 3 MAINTENANCE 3 1 INTRODUCTION 3 1 MAINTENANCE SCHEDULE 3 1 SECTION 4 REPAIR REPLACEMENT PROCEDURES 4 1 INTRODUCTIO...

Page 7: ...of Tables 1 1 Reference Documents 1 4 1 2 Glossary of Terms and Abbreviations 1 4 1 3 Nomenclature 1 4 1 4 Specifications 1 5 2 1 NIAC03 Module Cable Applications 2 3 3 1 Maintenance Schedule 3 1 A 1...

Page 8: ...module into operation only after reading and understanding this instruction MODULE DESCRIPTION The NIAC03 module is a single printed circuit board that uses one slot in a NTMU01 or NTMU02 Termination...

Page 9: ...input calibration for the 100 ohm RTD inputs on the IMASM03 module Individual channel precision calibration resistors Jumpers select correct resistance for zero or span calibra tion for each channel...

Page 10: ...epair parts training docu mentation etc available from Bailey Controls Company Appendix A Provides a quick reference of dipswitch settings for the IMASM03 Analog Slave Module HOW TO USE THIS MANUAL Re...

Page 11: ...level operations as directed by a master mod ule TMU Termination mounting unit A card cage that provides housing for INFI 90 Network 90 termination mod ules Network 90 is a registered trademark of Els...

Page 12: ...58 F 5 to 90 5 up to 55 C 131 F noncondensing 5 to 40 5 up to 70 C 158 F noncondensing Atmospheric Pressure Air Quality Sea level to 3 km 1 86 mi Noncorrosive Cooling Requirements No cooling is necess...

Page 13: ...d static safe practices when working with modules 1 Use Static Shielding Bag Keep the modules in static shielding bag until you are ready to install them in the system Save the bag for future use 2 Gr...

Page 14: ...input Each jumper selects zero or span for its respective input The IMAMM03 master module issues the calibration commands to the IMASM03 slave module being calibrated To calibrate the zero place the...

Page 15: ...NIAC03 Module Jumper Locations Figure 2 2 Cable Connections for the NIAC03 Module JUMPERS NIAC03 P1 1 29 T00618A CH1 SPAN ZERO CH7 SPAN ZERO CH6 SPAN ZERO CH5 SPAN ZERO CH4 SPAN ZERO CH3 SPAN ZERO CH2...

Page 16: ...he TMU backplane slot assigned to the NIAC03 module The cable should latch securely in place Card edge connector P1 of the NIAC03 mod ule connects to this end of the cable 5 Replace or add the cable r...

Page 17: ...one slot To install 1 Verify slot assignment of the NIAC03 module 2 Align the NIAC03 module with the guide rails in the TMU card rack and insert the module The NIAC03 module is ready for operation if...

Page 18: ...maintenance schedule MAINTENANCE SCHEDULE Execute the tasks in Table 3 1 at the specified intervals Table 3 1 Maintenance Schedule Task Interval Clean and tighten all power and grounding connections...

Page 19: ...er 2 Slide the calibration module out of the cabinet 3 Slide the new calibration module into the same slot as the module that was removed 4 Verify that cabling to the calibration module is correct 5 F...

Page 20: ...er and quantity 2 Model and serial numbers if applicable 3 Bailey instruction manual number page number and refer ence figure that identifies the part Order parts without commercial descriptions from...

Page 21: ...g the NIAC03 module Figure A 1 shows the IMASM03 module address select switch SW1 Table A 1 lists the binary addresses for setting SW1 Refer to the IMAMM03 instruction for more detailed informa tion t...

Page 22: ...ser 1 1 M Maintenance schedule 3 1 Module description 1 1 N NIAC03 Cable Applications 2 4 Cable Connections 2 3 Jumper Locations 2 3 Nomenclature 1 4 O Overview 1 1 R Reference documents 1 3 Replaceme...

Page 23: ...8756 ASIA PACIFIC 152 Beach Road Gateway East 20 04 Singapore 189721 Telephone 65 391 0800 Telefax 65 292 9011 EUROPE AFRICA MIDDLE EAST Via Puccini 2 16154 Genoa Italy Telephone 39 10 6582 943 Telefa...

Reviews: